78 WESTERN ELECTRIC COMPANY<br />
No . 9 Switchboard-Continued<br />
Notes:-<br />
1 . If a section is equipped with No . 22-A drops for ringdown trunks the subscriber line signal capacity<br />
will be reduced by 20 for each 15 of these trunks .<br />
2. The toll cord circuits shall all be wired so that they can be used for either magneto or <strong>com</strong>mon<br />
battery toll and local subscriber's lines, and with the repeating coil out on through toll connections<br />
or in on all connections . The standard arrangement is to leave the repeating coil out on the first 4 toll<br />
cords and in on the last cord .<br />
In addition, . to these sections we have standard rural and <strong>com</strong>bination subscriber and toll switching<br />
trunk sections . We will furnish <strong>com</strong>plete information on any of these upon request .<br />
The frame of this board is made of birch, finished to match mahogany . The dimensions of the standard<br />
sections are as follows : 6 ft . 3 in . high ; 2 ft . 5 in . wide ; 2 ft . 9 in . deep, from front of key shelf to rear door.<br />
The equipment in the rear of the section is accessible by removing the rear door.<br />
MAIN DISTRIBUTING FRAMES<br />
The main distributing frame is of iron construction, and may be either the wall type, or arranged,<br />
to mount separately . In the wall type the lower portion is designed to carry the protectors, consisting<br />
of heat coils and carbon block arresters, while the upper portion of the frame carries the fuses<br />
The separate type is designed so that one vertical may be added at a time, the vertical side carrying<br />
the protectors, consisting of heat coils and carbon block arresters, the horizontal side being equipped with<br />
terminal strips for connecting the outside lines .<br />
DESKS<br />
A wire chief's desk and chief operator's desk are provided for use with the No . 9 switchboard when<br />
necessary .<br />
POWER PLANT<br />
The power plants of the No . 9-D and No . 9-C switchboards are planned on the basis of 24 and 38 volt<br />
battery supply respectively . There is supplied a storage battery (usually E-7 cells), motor, charging<br />
generator, together with a power switchboard, on which are mounted the necessary instruments, such as<br />
voltmeter, ammeter, switches, fuses, etc .<br />
A ringing machine is not ordinarily used, as it is the usual practice to provide two interrupters to<br />
supply the ringing current .<br />
No. 10 SWITCHBOARD<br />
No . 10 Switchboard<br />
The No . 10 switchboard is used in offices up to 1600 lines capacity . In general, it may be said that<br />
the No . 10 switchboard possesses the operating and transmitting features of the No . 1 switchboard, it<br />
being provided with repeating coils in the cord circuits, and the functions of the cut-off relay being performed<br />
by a cut-off jack . The supervisory signals are controlled by back contact relays .<br />
The board is provided with answering jacks and associated lamp signals and lamp supervising signals<br />
arranged for positive supervision . It is designed for both single and multi-office districts .<br />
PRICES ON REQUEST