GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Industrial Process Calibrators cont’d.<br />
Fluke 690Bar Pressure Transducer to suit<br />
Calibrators 744 & 725<br />
FLU,700P31-690BAR (4724) AU<br />
For use with the Fluke 744 & &25 industrial<br />
calibrators. Range 100 to 690kPa, reference<br />
uncertainty .025%. Connection 1/4NPT and 1/4 ISO<br />
Includes 700LTP-1 pressure pump.<br />
Fluke 7Bar Pressure Transducer & Pump to suit FLU,744 & FLU,725<br />
FLU,700PD6-7BAR (4722) AU<br />
For use with the Fluke 744 & &25 industrial calibrators. Range 100 to 690kPa,<br />
reference uncertainty .025%. Connection 1/4NPT and 1/4 ISO Includes<br />
700LTP-1 pressure pump.<br />
Fluke 700S/W-DPC-TRACK Software for 744 Process Calibrator<br />
FLU,700S/W-DPC-TRACK (4720) AU<br />
Provides means of building and maintaining an instrumentation maintenance<br />
database for Fluke 743B & 744 Documenting Process Calibrators.<br />
Fluke 718 300G Pressure Calibrator<br />
FLU,718-300G (4761) AU<br />
Pressure source and milliamp measurement. Pressure<br />
specs -83 to 2068kPa ±0.05% of range. Max pressure<br />
2.6MPa. Current specs: 0.0001mA resolution, accuracy<br />
0.015%. Calibrate P/I (pressure to current) transmitters,<br />
measures pressure via a 1/8 inch NPT pressure fitting<br />
and an internal pressure sensor, source pressure,<br />
measure current up to 24mA, simultaneously display<br />
pressure and current measurements, supplies loop<br />
voltage, calculates percentage in percent mode,<br />
calculates mA error in percent error mode.<br />
Fluke 719 2Bar-30G Pressure Calibrator including Electric Pump<br />
FLU,719-30G (4763) AU<br />
2Bar, includes pump and precision 4 to 20mA measurement and source<br />
capability. The pump in this instrument is electric. Uncertainty 0.025%.<br />
Precision pressure adjustment vernier. Range -850mBar to 2Bar. Resolution<br />
1mBar. 4 to 20mA resolution .001mA .015%rdg + 2 counts.<br />
Fluke Pressure Calibrator 8Bar Includes<br />
Electric Pump<br />
FLU,719-100G (4762) AU<br />
8Bar, includes pump and precision 4 to 20mA measurement<br />
and source capability. The pump in this instrument is<br />
electric. Uncertainty 0.025%. Precision pressure<br />
adjustment vernier. Range -850mBar to 8Bar. Resolution<br />
1mBar. 4 to 20mA resolution 0.001mA 0.015%rdg + 2<br />
counts.<br />
Fluke 725 Process Calibrator<br />
FLU,725-NATA (4719) AU<br />
FLU,725 MY<br />
DC voltage measurement 0.025%, 300V max, source<br />
0.02%, 11V max. DC current measurement 0.025%,<br />
110mA max, source 0.01%, 22mA max. Resistance<br />
<br />
<br />
50kHz, source 1 count 20Hz to 5kHz. ‘K’ thermocouple<br />
measurement 0.3ºC, source 0.3ºC. Pt100 RTD<br />
measurement 0.5ºC, source 0.2ºC. Measures and<br />
simulates 4 to 20mA, t/c E,N, J, K, T, B, R, S, & C, 2,<br />
3 & 4 wire RTDs and frequency. Operates from drycell<br />
batteries. (Includes NATA calibration - AU).<br />
50<br />
www.techrentals.com.au<br />
Industrial Process Calibrators cont’d.<br />
Fluke 743 Calibrator<br />
FLU,743B MY<br />
Includes RS232 interface. DC voltage measurement 0.025%, 300V max,<br />
source 0.01%, 15V max. DC current measurement 0.025%, 110mA max,<br />
<br />
<br />
1 count 20Hz to 5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC<br />
Pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and simulates 4<br />
to 20mA, t/c E, N, J, K, T, B, R, S, & C, 2, 3 & 4 wire RTDs, frequency, test<br />
limit switches. Can use scaling factors for measurement & source. Built in<br />
calculator. Autostep function. Allows user entered values. Operates as an 8k<br />
point data logger. Note PC software only supports 15 tags.<br />
Fluke 744 DOC Calibrator with Hart<br />
FLU,744 (4725) AU/MY<br />
Documenting process calibrator which includes HART communication<br />
protocols for communicating with and setting up smart transmitters. RS232<br />
interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V<br />
max. DC current measurement 0.025%, 110mA max, source 0.01% 22mA max.<br />
Resistance measurement 0.05%, 11kOhm max, source 0.01% 11kOhm max.<br />
Frequency measurement 0.5%, +5, 40~500Hz, source 1 count 20~5kHz. ‘K’<br />
thermocouple measurement 0.3ºC, source 0.3ºC Pt100. RTDs measurement<br />
0.3ºC, source 0.1ºC. Measures and simulates 4~20mA, t/c E, N, J, K, T, B, R,<br />
S & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Uses scaling factors<br />
for measurement & source. Built in calculator. Autostep function. Allows user<br />
entered values. Operates as an 8k point data logger. Note PC software only<br />
supports 15 tags.<br />
Fluke 773 Milliamp Process Clamp Meter<br />
FLU,773 (4751) AU<br />
Measure 4 to 20mA control lines, PLC loops, transmitters<br />
or any 4 to 20mA line without breaking the loop. Capable<br />
of 0 to 20.99mA and 24 to 100mA with clamp. Source<br />
and simulate mA and voltage signals in circuit. 4 to 20mA<br />
scaled o/p.<br />
Fluke 789 Process Meter<br />
FLU,789 PROCESSMETER (4718) AU<br />
Standard multimeter functions with 2 to 20mA sink and source capability,<br />
including a 24V supply. HART 250 resistor, 20mA drive into 1,200.<br />
Simultaneous mA and % of scale readout on mA output. 25% manual step<br />
plus auto step and auto ramp on mA output. Min/max/average/hold/relative<br />
modes. Double size dual display. Accuracy, VDC 0.1% +1, VAC 0.7% +2, mA<br />
DC 0.05% +2, frequency 0.005% +1.<br />
Halstrup KAL84 0-1kPa Portable<br />
Pressure Calibrator<br />
HAL,KAL84 (4792) AU<br />
Portable battery operated 0-1kPa (0-10mBar)<br />
low pressure calibrator. Linearity ±0.5% ±1<br />
digit, hysteresis 0.1%, medium - air and all non<br />
aggressive gases, pressure connections 6.5mm hose NW5, interior tubing<br />
5mmØ. Analogue output 0 to 1V, display 4.5 digit, power supply via mains<br />
adaptor 100 to 240VAC & NiCd rechargable battery pack.<br />
Jofra DPC-500 Documenting Pressure<br />
Calibrator 1000Bar NATA<br />
JOF,DPC-1000-NATA (4782) AU<br />
Documenting pressure calibrator is used for<br />
high precision calibration of pressure gauges,<br />
pressure transmitters, digital manometers,<br />
pressure switches, overpressure protection valves<br />
etc. Measure pressure at 1,000Bar or 14,500psi, voltage 0 to 10V, current<br />
0 to 20mA and 4 to 20mA, and supplies 24VDC as source for transmitters.<br />
Accuracy ±0.025% F.S. Supplied with Druck PV212 1000Bar hand pump<br />
and calibration software. 15 user selectable engineering units including user<br />
defined. Nata Calibrated.