Power Analysers & Recorders cont'd. - Ferret
Power Analysers & Recorders cont'd. - Ferret
Power Analysers & Recorders cont'd. - Ferret
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
www.techrentals.com.au<br />
Data Loggers cont’d.<br />
Hioki 8422-51 32 Channel Data Logger<br />
HIO,8422-51 (4273) AU<br />
32 analogue, 4 pulse input channels data logger with colour display, PCMCIA<br />
card slot, LAN interface built in, TCP/IP communication supports real time PC<br />
logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1 VDC, 10 VDC, 60<br />
VDC, 1-5V DC f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, B, -100 to<br />
100ºC, -200 to 500ºC, -200 to 2,000ºC, Pulse input, accumulation 50,000C<br />
f.s, 500,000C f.s, 5MC f.s, 100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s)<br />
f.s. Recording interval is selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s,<br />
10s, 20s, 30s, 1min, 2min, 5min. Max sampling rate is dependent upon type<br />
of input signal. Internal Memory 8MB, 512MB PCMCIA FLASH card, 9334<br />
Logger Communicator software, 9642 LAN cable, 9641 pulse signal input<br />
cable all supplied.<br />
Hioki Kit of Three 9322 Differential Probe High Voltage<br />
True RMS Interface<br />
HIO,9322-KIT (4119) AU<br />
Used with many memory recorders, eg. Hioki 8835. Operating modes 3.<br />
DC mode for waveform monitor output DC to 3MHz, AC mode detection of<br />
power surge noise 1kHz to 10MHz. Rectified true RMS output of DC & AC<br />
voltages. 40Hz to 100kHz response speed 200ms or less. Max voltage DC<br />
2kV, AC 1kV CATII, AC/DC 600V CATIII, balanced differential input 1/1,000<br />
divider.<br />
Testo 177-H1 Logger with Display<br />
TES,177-H1 MY<br />
Parameters: humidity/temperature/dew point. Sensors: humidity sensor/<br />
NTC (internal). Number of channels: 4. Measuring range: 0 to 100%RH and<br />
-20 to 70ºC (internal). Memory: 48,000 readings.<br />
Testo 177-T4 Logger with Display<br />
TES,177-T4 MY<br />
Parameters: temperature (C/F). Sensors: thermocouple type-K. Number<br />
of channels: 4 (external). Measuring range: -100 to 1,000 ºC (external).<br />
Memory: 48,000 readings.<br />
Pressure & Humidity Transducers<br />
Druck PTX1400 4Bar Pressure Transducer<br />
DRU,PTX1400-4 (4307) AU<br />
Output 4 to 20mA. Requires 9 to 36VDC. Supplied with 12V<br />
plug pack. Pressure input connector G ¼” female.<br />
Druck PTX1400-25 25Bar Pressure Transducer 4 to 20mA<br />
DRU,PTX1400-25 (4302) AU<br />
Output 4 to 20mA output, 0 to 25Bar input. Requires 9 to 28VDC, supplied<br />
with 12V, 500mA power pack.<br />
Druck PTX1400 40Bar Pressure Transducer 4 to 20mA<br />
DRU,PTX1400-40 (4303) AU<br />
Output 4 to 20mA. Requires 9 to 36V DC, supplied with 12V plug pack.<br />
Druck PTX 1400 600Bar Pressure Transducer<br />
DRU,PTX1400-600 (4305) AU<br />
Output 4 to 20mA. Requires 9 to 32VDC, supplied with 12V plug pack.<br />
Fluke PV350 Vacuum/Pressure Indicator<br />
FLU,PV350 (4321) AU<br />
Can be used with a digital multimeter (eg Fluke 189)<br />
to act as an indicator. Range, pressure to 4137kPa<br />
and vacuum 0 to 76cmHg. Results in either psi or kPa.<br />
Connector ½”NPT (m). Cable 2.4m provided. Battery<br />
powered.<br />
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
55<br />
Pressure & Humidity Transducers<br />
cont’d.<br />
RS Type 461-313 Pressure Transducer Range<br />
-1 to 24Bar G<br />
RS,TYPE 461-313 (4301) AU<br />
Range -1 to 24Bar G. Output 4 to 20mA.<br />
Schaevitz P1241 10,000PSI 0 to 5V Pressure Transducer incl Snubber<br />
SHA,P1241-10000 (4322) AU<br />
10,000psi, includes snubber, 0 to 5V output.<br />
Schaevitz P3061-4D 4PSI Differential Pressure Transducer<br />
SHA,P3061-4D (4313) AU<br />
4psi. LVDT type with built-in amplifier. Output 0 to 5VDC. Operates from 10 to<br />
32VDC or AC mains.<br />
Trafag 8204 1Bar, 4 to 20mA, Differential Pressure Transducer<br />
TRA,8204-1D-20A (4311) AU<br />
Accuracy ±0.3% FS. Overpressure 10Bar. Output 4 to 20mA. Pressure<br />
connection G ¼” male. Bandwidth 1kHz. Media temperature 125ºC. IP65<br />
rated. <strong>Power</strong> supply 10 to 30V.<br />
Vaisala HMP 135Y 160ºC Humidity Probe<br />
VAI,HMP-135Y (4581) AU<br />
High temperature humidity and temperature transmitter. Sensor head<br />
operates from 0 to 180ºC. Measurement range 0 to 100%RH. Accuracy of<br />
1%RH at 20ºC. Output 0 to 5V DC. Other outputs easily set including 4 to<br />
20mA. Operates from 0 to 160ºC.<br />
Vaisala HMP 235Y 180ºC Humidity Probe<br />
VAI,HMP-235Y (4582) AU<br />
High temperature humidity and temperature transmitter. Sensor head<br />
operates from 0 to 160ºC. Measurement range 0 to 100%RH. Accuracy of<br />
1%RH at 20ºC. Output 0 to 5VDC. Other outputs easily set including 4 to<br />
20mA. Operates from 15 to 30V DC or AC mains.<br />
Vega Bar 20 0 to 1Bar Transducer with Display<br />
VEG,BAR20-1 (4314) AU<br />
Output 4 to 20mA. LCD display and is rated IP65. Over pressure resistant to<br />
10Bar & -1Bar. Measurement accuracy 0.5%, linearity deviation 0.085%. May<br />
be set to bar, psi, kpa, mpa,mmH 2 O, mH 2 O & mbar. Output can be 4 to 20mA<br />
or 20 to 4mA. Integration time 0 to 10s. Density factor may be entered for mm<br />
and m, output simulation indication module has 20 segment bar graph and 4<br />
digit display which may be scaled (has factory default reset). Supply required<br />
12 to 36VDC.<br />
Pressure Vacuum Gauges/<strong>Recorders</strong><br />
Bristol Babcock 10,000PSI Mech Chart Recorder<br />
BRI,10000-NATA (4328) AU<br />
Circular pressure chart recorder 10,000psi. 12”Ø. Accuracy ±0.5% NATA<br />
calibrated. Fitted with 2 speed spring wound chart drive giving 7d or 24h<br />
recording. Pressure connection ¼”NPT.<br />
Crystal XP2i Digital Logging Pressure<br />
Gauge 7Bar NATA calibrated<br />
CRY,XP2I-100-NATA (4341) AU<br />
Range 7Bar resolution 0.1mBar. Accuracy 1.4 to 7Bar<br />
±0.1% of reading. 0 to 1.4Bar ±1.4mBar. Vacuum<br />
±17.5mBar. Has a 6000 point logging capability. Logging<br />
intervals from 1s up can be set. Logs either actual<br />
pressure, average pressure or average pressure with