Adjusting the Weapon’s Zero. When the shot group is satisfactory and the CS deviates<br />

from the CP more than 5 cm, the sights are changed in accordance with the format<br />

below:<br />

Elevation –<br />

If the CS is lower than the CP (point of aim), rotate the front sight post down<br />

(clockwise).<br />

If the CS is higher than the CP (point of aim), rotate the front sight post up<br />

(clockwise).<br />

Windage –<br />

If the CS deviates to the right of the CP (point of aim, drift the blade base (front<br />

sight) to the right.<br />

If the CS deviates to the left of the point of aim, drift the blade base (front sight)<br />

to the left.<br />

How much the blade base is moved (i.e., raised or lowered) depends on how much the<br />

CS deviates and the length of the aiming line as shown in tables 2 and 3.<br />

CS deviation<br />

(cm)<br />

Blade moved<br />

horizontally<br />

(mm)<br />

Table 1. Windage-Zero Adjustments<br />

5 7.5 10 12.5 15 17.5 20 22 25 27.5 30<br />

.33<br />

.5<br />

.66<br />

.88<br />

1<br />

1.17<br />

1.33<br />

1.5<br />

1.66<br />

1.83<br />

Table 2. Elevation-Zero Adjustments<br />

Rotation of blade (full circle) 1/4 ½ 3/4 1<br />

Vertical deviation of CS (cm) 3 6 9 12<br />

The operator adjusts the blade base or the elevation under the supervision of his<br />

supervisor. Move the blade base sidewise until it is aligned with the external surface of<br />

the front sight base.<br />

After the blade base is moved or its elevation adjusted by means of rotation, re-fire the<br />

semi-automatic fire and automatic fire zero as outlined above. If this proves inadequate,<br />

make further correction, and repeat firing.<br />

If owing to a significant deviation of the CS, the blade base needs to be moved to the<br />

right (or left) more than allowed, another marksman carries out the firing. If the results<br />

are the same, the testing is discontinued and the machinegun is sent in for repair as<br />

inaccurate.<br />

If results are achieved with the semi-automatic fire zero, but the CS continues to be<br />

more than 5 cm away from the CP, the proper functioning of the machinegun must be<br />