7.8 Barometric Pressure Input<br />
7.8.1 BAR_IN_MSB, BAR_IN_LSB (0x14, 0x15)<br />
Barometric input for altitude calculations. Input is equivalent sea level pressure for measurement location.<br />
Value is input in 2 Pa units.<br />
Units are input as unsigned 16-bit integers. The default value is 101,326 Pa. The default value can be changed by writing to<br />
this register<br />
Table 39. BAR_IN_MSB Register<br />
7 6 5 4 3 2 1 0<br />
R<br />
W<br />
BAR[15] BAR[14] BAR[13] BAR[12] BAR[11] BAR[10] BAR[9] BAR[8]<br />
Reset 1 1 0 0 0 1 0 1<br />
Table 40. BAR_IN_LSB Register<br />
7 6 5 4 3 2 1 0<br />
R<br />
W<br />
BAR[7] BAR[6] BAR[5] BAR[4] BAR[3] BAR[2] BAR[1] BAR[0]<br />
Reset 1 1 1 0 0 1 1 1<br />
7.9 Pressure/Altitude Target<br />
7.9.1 P_TGT_MSB, P_TGT_LSB (0x16, 0x17)<br />
Altitude/Pressure target value. This value works in conjunction with the window value (P_WND_MSB and P_WND_LSB).<br />
In Altitude mode, the register value is 16-bit 2’s complement value in meters.<br />
In Pressure mode, the value is 16-bit unsigned value in 2 Pa units.<br />
Table 41. P_TGT_MSB Register<br />
7 6 5 4 3 2 1 0<br />
R<br />
W<br />
P_TGT15 P_TGT14 P_TGT13 P_TGT12 P_TGT11 P_TGT10 P_TGT9 P_TGT8<br />
Reset 0 0 0 0 0 0 0 0<br />
Table 42. P_TGT_LSB Register<br />
7 6 5 4 3 2 1 0<br />
R<br />
W<br />
P_TGT7 P_TGT6 P_TGT5 P_TGT4 P_TGT3 P_TGT2 P_TGT1 P_TGT0<br />
Reset 0 0 0 0 0 0 0 0<br />
7.10 Temperature Target<br />
7.10.1 T_TGT (0x18)<br />
Temperature target value input in 2’s complement value in °C.<br />
Table 43. T_TGT Register<br />
7 6 5 4 3 2 1 0<br />
R<br />
W<br />
T_TGT7 T_TGT6 T_TGT5 T_TGT4 T_TGT3 T_TGT2 T_TGT1 T_TGT0<br />
Reset 0 0 0 0 0 0 0 0<br />
MPL3115A2<br />
Sensors<br />
Freescale Semiconductor, Inc. 29