7.17.3 CTRL_REG3 (Interrupt CTRL Register) (0x28)<br />
Table 62. CTRL_REG3 Register<br />
7 6 5 4 3 2 1 0<br />
R 0<br />
0<br />
IPOL1 PP_OD1<br />
IPOL2 PP_OD2<br />
W<br />
Reset 0 0 0 0 0 0 0 0<br />
Table 63. CTRL_REG3 Description<br />
Name<br />
IPOL1<br />
PP_OD1<br />
IPOL2<br />
PP_OD2<br />
Description<br />
The IPOL bit selects the polarity of the interrupt signal. When IPOL is ‘0’ (default value) any interrupt event will signalled<br />
with a logical ‘0'. Interrupt Polarity active high, or active low on interrupt pad INT1.<br />
Default value: 0<br />
0: Active low<br />
1: Active high<br />
This bit configures the interrupt pin to Push-Pull or in Open Drain mode. The default value is 0 which corresponds to<br />
Push-Pull mode. The open drain configuration can be used for connecting multiple interrupt signals on the same interrupt<br />
line. Push-Pull/Open Drain selection on interrupt pad INT1.<br />
Default value: 0<br />
0: Internal Pullup<br />
1: Open drain<br />
Interrupt Polarity active high, or active low on interrupt pad INT2.<br />
Default value: 0<br />
0: Active low<br />
1: Active high<br />
Push-Pull/Open Drain selection on interrupt pad INT2.<br />
Default value: 0<br />
0: Internal Pull-up<br />
1: Open drain<br />
7.17.4 CTRL_REG4 [Interrupt Enable Register] (0x29)<br />
The corresponding functional block interrupt enable bit allows the functional block to route its event detection flags to the system’s<br />
interrupt controller. The interrupt controller routes the enabled functional block interrupt to the INT1 or INT2 pin.<br />
Table 64. CTRL_REG4 Register<br />
7 6 5 4 3 2 1 0<br />
R INT_EN_DRDY INT_EN _FIFO INT_EN_PW INT_EN_TW INT_EN_PTH INT_EN_TTH INT_EN_PCHG INT_EN_TCHG<br />
W<br />
Reset 0 0 0 0 0 0 0 0<br />
Table 65. Interrupt Enable Register Description<br />
Interrupt Enable<br />
INT_EN_DRDY<br />
INT_EN_FIFO<br />
INT_EN_PW<br />
Interrupt Enable.<br />
Default value: 0<br />
0: Data Ready interrupt disabled<br />
1: Data Ready interrupt enabled<br />
Interrupt Enable.<br />
Default value: 0<br />
0: FIFO interrupt disabled<br />
1: FIFO interrupt enabled<br />
Interrupt Enable.<br />
Default value: 0<br />
0: Pressure window interrupt disabled<br />
1: Pressure window interrupt enabled<br />
Description<br />
MPL3115A2<br />
Sensors<br />
34 Freescale Semiconductor, Inc.