7.17.3 CTRL_REG3 (Interrupt CTRL Register) (0x28)<br />

Table 62. CTRL_REG3 Register<br />

7 6 5 4 3 2 1 0<br />

R 0<br />

0<br />

IPOL1 PP_OD1<br />

IPOL2 PP_OD2<br />

W<br />

Reset 0 0 0 0 0 0 0 0<br />

Table 63. CTRL_REG3 Description<br />

Name<br />

IPOL1<br />

PP_OD1<br />

IPOL2<br />

PP_OD2<br />

Description<br />

The IPOL bit selects the polarity of the interrupt signal. When IPOL is ‘0’ (default value) any interrupt event will signalled<br />

with a logical ‘0'. Interrupt Polarity active high, or active low on interrupt pad INT1.<br />

Default value: 0<br />

0: Active low<br />

1: Active high<br />

This bit configures the interrupt pin to Push-Pull or in Open Drain mode. The default value is 0 which corresponds to<br />

Push-Pull mode. The open drain configuration can be used for connecting multiple interrupt signals on the same interrupt<br />

line. Push-Pull/Open Drain selection on interrupt pad INT1.<br />

Default value: 0<br />

0: Internal Pullup<br />

1: Open drain<br />

Interrupt Polarity active high, or active low on interrupt pad INT2.<br />

Default value: 0<br />

0: Active low<br />

1: Active high<br />

Push-Pull/Open Drain selection on interrupt pad INT2.<br />

Default value: 0<br />

0: Internal Pull-up<br />

1: Open drain<br />

7.17.4 CTRL_REG4 [Interrupt Enable Register] (0x29)<br />

The corresponding functional block interrupt enable bit allows the functional block to route its event detection flags to the system’s<br />

interrupt controller. The interrupt controller routes the enabled functional block interrupt to the INT1 or INT2 pin.<br />

Table 64. CTRL_REG4 Register<br />

7 6 5 4 3 2 1 0<br />

R INT_EN_DRDY INT_EN _FIFO INT_EN_PW INT_EN_TW INT_EN_PTH INT_EN_TTH INT_EN_PCHG INT_EN_TCHG<br />

W<br />

Reset 0 0 0 0 0 0 0 0<br />

Table 65. Interrupt Enable Register Description<br />

Interrupt Enable<br />

INT_EN_DRDY<br />

INT_EN_FIFO<br />

INT_EN_PW<br />

Interrupt Enable.<br />

Default value: 0<br />

0: Data Ready interrupt disabled<br />

1: Data Ready interrupt enabled<br />

Interrupt Enable.<br />

Default value: 0<br />

0: FIFO interrupt disabled<br />

1: FIFO interrupt enabled<br />

Interrupt Enable.<br />

Default value: 0<br />

0: Pressure window interrupt disabled<br />

1: Pressure window interrupt enabled<br />

Description<br />