Table 65. Interrupt Enable Register Description<br />
INT_EN_TW<br />
INT_EN_PTH<br />
INT_EN_TTH<br />
INT_EN_PCHG<br />
INT_EN_TCHG<br />
Interrupt Enable.<br />
Default value: 0<br />
0: Temperature window interrupt disabled<br />
1: Temperature window interrupt enabled.<br />
Interrupt Enable.<br />
Default value: 0<br />
0: Pressure Threshold interrupt disabled<br />
1: Pressure Threshold interrupt enabled.<br />
Interrupt Enable.<br />
Default value: 0<br />
0: Temperature Threshold interrupt disabled<br />
1: Temperature Threshold interrupt enabled.<br />
Interrupt Enable.<br />
Default value: 0<br />
0: Pressure Change interrupt disabled<br />
1: Pressure Change interrupt enabled.<br />
Interrupt Enable.<br />
Default value: 0<br />
0: Temperature Change interrupt disabled<br />
1: Temperature Change interrupt enabled.<br />
MPL3115A2<br />
Sensors<br />
Freescale Semiconductor, Inc. 35