Table 65. Interrupt Enable Register Description<br />

INT_EN_TW<br />

INT_EN_PTH<br />

INT_EN_TTH<br />

INT_EN_PCHG<br />

INT_EN_TCHG<br />

Interrupt Enable.<br />

Default value: 0<br />

0: Temperature window interrupt disabled<br />

1: Temperature window interrupt enabled.<br />

Interrupt Enable.<br />

Default value: 0<br />

0: Pressure Threshold interrupt disabled<br />

1: Pressure Threshold interrupt enabled.<br />

Interrupt Enable.<br />

Default value: 0<br />

0: Temperature Threshold interrupt disabled<br />

1: Temperature Threshold interrupt enabled.<br />

Interrupt Enable.<br />

Default value: 0<br />

0: Pressure Change interrupt disabled<br />

1: Pressure Change interrupt enabled.<br />

Interrupt Enable.<br />

Default value: 0<br />

0: Temperature Change interrupt disabled<br />

1: Temperature Change interrupt enabled.<br />

MPL3115A2<br />

Sensors<br />