3.2 Absolute Maximum Ratings<br />

Stresses above those listed as “absolute maximum ratings” may cause permanent damage to the device. This is a stress rating<br />

only and functional operation of the device under these conditions is not implied. Exposure to maximum rating conditions for extended<br />

periods may affect device reliability.<br />

Table 5. Maximum Ratings<br />

Characteristic Symbol Value Unit<br />

Maximum Applied Pressure P max 500 kPa<br />

Supply Voltage V DD -0.3 to 3.6 V<br />

Interface Supply Voltage V DDIO -0.3 to 3.6 V<br />

Input Voltage on any Control Pin (SCL, SDA) VIN -0.3 to V DDIO + 0.3 V<br />

Operating Temperature Range T OP -40 to +85 °C<br />

Storage Temperature Range T STG -40 to +125 °C<br />

Table 6. ESD And Latch-up Protection Characteristics<br />

Rating Symbol Value Unit<br />

Human Body Model HBM ±2000 V<br />

Machine Model MM ±200 V<br />

Charge Device Model CDM ±500 V<br />

Latch-up Current at T = 85°C — ±100 mA<br />

This is a mechanical shock sensitive device, improper handling can cause permanent damage to the part or<br />

cause the part to otherwise fail.<br />

This is an ESD sensitive device, improper handling can cause permanent damage to the part.<br />

MPL3115A2<br />

Sensors<br />

Freescale Semiconductor, Inc. 9