<strong>CMG</strong>-<strong>40T</strong>-1<br />
Handheld Control Unit's Display Select knob. If using a HCU, also<br />
check that the Centring Select knob is set to OFF.<br />
2. If the vertical component needs adjusting, remove the cap on the lid<br />
which protects the Verticalpot with a flat-bladed screwdriver (provided).<br />
3. Insert the screwdriver through the opening, and engage the pot. An LED<br />
flashlight may be useful for locating the head.<br />
4. Turn the pot either way until the offset readout is as close to 0 V as<br />
possible.<br />
5. Repeat steps 2 – 5 for the north/south and east/west components.<br />