<strong>CMG</strong>-<strong>6T</strong><br />
You will need access to a PC with a 9-pin RS232 port, and a 12 V<br />
power source.<br />
1. Install Scream! on your PC and run it.<br />
2. Connect the GPS receiver to the <strong>CMG</strong>-DM24 using the brown<br />
cable supplied with the digitiser. Position the GPS receiver so<br />
that it has a good view of the sky. If you do not have a view of<br />
the sky, you can operate the sensor without a GPS unit, but<br />
timing information may be inaccurate.<br />
3. Connect the grey data cable between the <strong>CMG</strong>-<strong>6T</strong> and the<br />
SENSOR A .connector on the digitiser.<br />
4. Using the blue/grey combined data/power cable that is included<br />
with the <strong>CMG</strong>-DM24, connect the digitiser to the PC's serial port<br />
and then to a 12V power supply.<br />
The instrument is now fully operational, and will already be<br />
producing data.<br />
5. After a few seconds you should see the digitizer appear under<br />
Network – Local – Com1 in the left-hand panel of Scream!'s<br />
main window. (If your PC has multiple serial ports, it may<br />
appear under some other Com port name.) Soon after, data<br />
streams will begin appearing in the right-hand panel. Streams<br />
with higher sample rates will appear sooner than those with<br />
lower sample rates.<br />
If this does not happen, check all connections, and ensure the<br />
power supply is providing the correct voltage and current.<br />
10 Issue B