10 5<br />

xln<br />

I<br />

0<br />

hager<br />

1 0,8<br />

xln<br />

ln(A)<br />

630<br />

test<br />

Connection Sets<br />

<strong>univers</strong> N<br />

Decsription Technical Gap Locking Pack Best.Nr.<br />

Data torque Quantity<br />

UM05A<br />

Busbar connector 12 x 5 mm, 5 Pole 40 mm 5 Nm 1 UM05A<br />

always order connection 12 x 10 mm, 5 Pole 40 mm 5 Nm 1 UM05B<br />

pieces U842I + P86D7/D8 20 x 5/10 mm, 4 Pole 60 mm 5 Nm 1 UM05C<br />

with FP... + ZP... boards 20 x 5/10 mm, 1 Pole 60 mm 5 Nm 1 UM05D<br />

Connection set FZ776 12 x 5 mm, 4 Pole 60 mm 5 Nm 1 UM05G<br />

12 x 10 mm, 4 Pole 60 mm 5 Nm 1 UM05H<br />

12 x 5 mm, 1 Pole 60 mm 5 Nm 1 UM05K<br />

12 x 10 mm, 1 Pole 60 mm 5 Nm 1 UM05L<br />

for FT... and FA... cabinets 30 x 5/10 mm, 1 Pole 60 mm 20 Nm 1 UM05F<br />

beside each other 30 x 5/10 mm, 4 Pole 60 mm 20 Nm 1 UM05E<br />

Leave room for the 12 x 5/10 mm, 1 Pole 40/60 mm 5 Nm 1 UM05M<br />

connectors - lower carrier rails 20 x 5/10 mm, 1 Pole 60 mm 5 Nm 1 UM05N<br />

30 x 10 mm, 1 Pole 100 mm 20 Nm 1 UM05R<br />

for equipment kits NH00<br />

40 x 10 mm, 3 Pole 185 mm 40 Nm 1 UM05S1<br />

for equipment kits NH1/2/3<br />

• Flexible cable (NSGAFÖU<br />

U 0 /U = 1.8 kV/3 kV kurz-<br />

(short-circuit protected and<br />

earthed), including busbar<br />

terminals and depending on<br />

the application, cable ends<br />

and/or cable lugs, incl.<br />

Labelling L1, L2, L3 (N)<br />

• pre cut and ready made for<br />

various applicatons<br />

• 3 Pole or 4 Pole<br />

Pack Quantity: 1<br />

Connection<br />

Sets<br />

125 A<br />

(25 mm 2 )<br />

160 A<br />

(35 mm 2 )<br />

250 A<br />

(70 mm 2 )<br />

400 A<br />

(2 x 70 mm 2 )<br />

630 A<br />

(2 x 95 mm 2 )<br />

from busbar<br />

kit 300mm<br />

high<br />

with<br />

terminals:<br />

K96T<br />

K96T<br />

K96V<br />

K96V<br />

K96L<br />

ZÜGIG SCHALTEN<br />

OPERATE QUICKLY<br />

hager<br />

to isolating<br />

switch<br />

NH00/1/2/3<br />

NH00<br />

UL01B5<br />

NH1<br />

UL02B7<br />

NH2<br />

UL04B5<br />

NH3<br />

UL07B6<br />

UL01B4<br />

(1)<br />

(1)<br />

to fuse base<br />

NH00/1/2/3<br />

NH00<br />

UL03B3<br />

NH1<br />

UL01B4<br />

NH2<br />

2 x UL01B4<br />

(1)<br />

UL01B5<br />

to isolating<br />

switch NH00<br />

in strip<br />

config.<br />

UL05B4<br />

(1), (2), (3)<br />

2 x UL05B4<br />

(1), (2), (3)<br />

UL05B6<br />

(1), (2), (3)<br />

UL05B4<br />

hager HN 630<br />

to<br />

MCB/MCCB -<br />

range HN../<br />

HE.. or HC... /<br />

NI...<br />

UL04B2 UL01B3 UL01B7<br />

2 x UL02B7<br />

(1)<br />

UL03B6<br />

(1)<br />

UL01B4<br />

to MCCB -<br />

range HA..<br />

UL01B3 UL01B4 2 x UL02B4<br />

(1)<br />

UL01B6<br />

(1), (4)<br />

(1) Because of the space taken by the connection terminals, use 2 field busbar kit.<br />

(2) 4 Pole<br />

(3) For connection, a divider must be omitted or placed in a spare field.<br />

(4) includes terminals KS24C<br />

242