The electrician's system: univers N - Hager
The electrician's system: univers N - Hager
The electrician's system: univers N - Hager
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
10 5<br />
xln<br />
I<br />
0<br />
hager<br />
1 0,8<br />
xln<br />
ln(A)<br />
630<br />
test<br />
Connection Sets<br />
<strong>univers</strong> N<br />
Decsription Technical Gap Locking Pack Best.Nr.<br />
Data torque Quantity<br />
UM05A<br />
Busbar connector 12 x 5 mm, 5 Pole 40 mm 5 Nm 1 UM05A<br />
always order connection 12 x 10 mm, 5 Pole 40 mm 5 Nm 1 UM05B<br />
pieces U842I + P86D7/D8 20 x 5/10 mm, 4 Pole 60 mm 5 Nm 1 UM05C<br />
with FP... + ZP... boards 20 x 5/10 mm, 1 Pole 60 mm 5 Nm 1 UM05D<br />
Connection set FZ776 12 x 5 mm, 4 Pole 60 mm 5 Nm 1 UM05G<br />
12 x 10 mm, 4 Pole 60 mm 5 Nm 1 UM05H<br />
12 x 5 mm, 1 Pole 60 mm 5 Nm 1 UM05K<br />
12 x 10 mm, 1 Pole 60 mm 5 Nm 1 UM05L<br />
for FT... and FA... cabinets 30 x 5/10 mm, 1 Pole 60 mm 20 Nm 1 UM05F<br />
beside each other 30 x 5/10 mm, 4 Pole 60 mm 20 Nm 1 UM05E<br />
Leave room for the 12 x 5/10 mm, 1 Pole 40/60 mm 5 Nm 1 UM05M<br />
connectors - lower carrier rails 20 x 5/10 mm, 1 Pole 60 mm 5 Nm 1 UM05N<br />
30 x 10 mm, 1 Pole 100 mm 20 Nm 1 UM05R<br />
for equipment kits NH00<br />
40 x 10 mm, 3 Pole 185 mm 40 Nm 1 UM05S1<br />
for equipment kits NH1/2/3<br />
• Flexible cable (NSGAFÖU<br />
U 0 /U = 1.8 kV/3 kV kurz-<br />
(short-circuit protected and<br />
earthed), including busbar<br />
terminals and depending on<br />
the application, cable ends<br />
and/or cable lugs, incl.<br />
Labelling L1, L2, L3 (N)<br />
• pre cut and ready made for<br />
various applicatons<br />
• 3 Pole or 4 Pole<br />
Pack Quantity: 1<br />
Connection<br />
Sets<br />
125 A<br />
(25 mm 2 )<br />
160 A<br />
(35 mm 2 )<br />
250 A<br />
(70 mm 2 )<br />
400 A<br />
(2 x 70 mm 2 )<br />
630 A<br />
(2 x 95 mm 2 )<br />
from busbar<br />
kit 300mm<br />
high<br />
with<br />
terminals:<br />
K96T<br />
K96T<br />
K96V<br />
K96V<br />
K96L<br />
ZÜGIG SCHALTEN<br />
OPERATE QUICKLY<br />
hager<br />
to isolating<br />
switch<br />
NH00/1/2/3<br />
NH00<br />
UL01B5<br />
NH1<br />
UL02B7<br />
NH2<br />
UL04B5<br />
NH3<br />
UL07B6<br />
UL01B4<br />
(1)<br />
(1)<br />
to fuse base<br />
NH00/1/2/3<br />
NH00<br />
UL03B3<br />
NH1<br />
UL01B4<br />
NH2<br />
2 x UL01B4<br />
(1)<br />
UL01B5<br />
to isolating<br />
switch NH00<br />
in strip<br />
config.<br />
UL05B4<br />
(1), (2), (3)<br />
2 x UL05B4<br />
(1), (2), (3)<br />
UL05B6<br />
(1), (2), (3)<br />
UL05B4<br />
hager HN 630<br />
to<br />
MCB/MCCB -<br />
range HN../<br />
HE.. or HC... /<br />
NI...<br />
UL04B2 UL01B3 UL01B7<br />
2 x UL02B7<br />
(1)<br />
UL03B6<br />
(1)<br />
UL01B4<br />
to MCCB -<br />
range HA..<br />
UL01B3 UL01B4 2 x UL02B4<br />
(1)<br />
UL01B6<br />
(1), (4)<br />
(1) Because of the space taken by the connection terminals, use 2 field busbar kit.<br />
(2) 4 Pole<br />
(3) For connection, a divider must be omitted or placed in a spare field.<br />
(4) includes terminals KS24C<br />
242