The external wiring must be earthed, with correct polarity and in<br />

accordance with current standards.<br />

The manufacturer declines any responsibility <strong>for</strong> damages to<br />

persons or others ca<strong>use</strong>d by the incorrect installation of the<br />

appliance earthing. This includes failure to comply with current<br />

standards.<br />

Electrical components have been tested to meet the equivalent<br />

requirements of the BEAB.<br />

• Do not <strong>use</strong> cable greater than 8 mm in diameter <strong>for</strong> the<br />

electrical connections.<br />

All system components must be of an approved type.<br />

• Do not interrupt the mains supply with a time switch or<br />

programmer.<br />

The boiler is suitable <strong>for</strong> installation in bathroom zones 2 and 3.<br />

10.2 Access to main board<br />

1<br />

2 3<br />

Key<br />

1 Control box<br />

2 Control box securing screw<br />

3 Mains cable<br />

2<br />

• Keep a distance of a maximum of 30 mm between connector<br />

(1) and the start of the insulation (3).<br />

• If using single core wires are <strong>use</strong>d(2) ensure that the are<br />

wrapped together in an insulating sheath.<br />

• Fix the cables in the cable-clamp on the eBox.<br />

10.4 Electrical wiring<br />

Connection of the whole electrical system and any heating<br />

system controls to the electrical supply must be through a<br />

common isolator.<br />

Isolation should preferably be by a double pole switched f<strong>use</strong>d<br />

spur box having a minimum contact separation of 3mm on each<br />

pole. The f<strong>use</strong>d spur box should be readily accessible and<br />

preferably adjacent to the boiler. It should be identifi ed as to its<br />

<strong>use</strong>.<br />

A f<strong>use</strong>d (3A) three pin plug and shuttered socket outlet may be<br />

<strong>use</strong>d instead of a f<strong>use</strong>d spur box provided that it is not <strong>use</strong>d in a<br />

room containing a fi xed bath or shower.<br />

• Connect the appliance's power cable to the 230 V singlephase<br />

network + earth.<br />

• Connect the appliance in accordance with the live and<br />

neutral connections.<br />

230V permanent supply<br />

a<br />

All cables connected to the appliance should<br />

be permanently fixed to the wall. Ensure the<br />

incoming electrical cable is clamped in the clamp<br />

provided.<br />

2<br />

• Remove the control box securing screws (2) and pull the<br />

control box (1) <strong>for</strong>ward into the service position.<br />

• Route the mains cable (3) through the grommet and connect<br />

to the electrical plug on the controls board.<br />

1<br />

10.3 Main board<br />

1 2 3<br />

3<br />

30mm<br />

max<br />

Key<br />

1 Connector<br />

2 Electrical wires<br />

3 Insulation<br />

When you connect the electrical wires to a connector on the<br />

electronic board:<br />

Key<br />

1 230V permanent supply<br />

2 Main board terminal block: = Mains earth, N = Mains<br />

neutral<br />

L = Mains live<br />

3 F<strong>use</strong><br />

4 Double pole connector<br />

• Connect mains supply as described.<br />

4<br />

- 18 - Service Call 0844 736 9138, Technical Help (Chargeable) Call 0906 802 0253