18.5 Expansion vessel<br />
2<br />
There is a fi lter fi tted that protects the plate heat exchanger from<br />
blockage.<br />
• After draining the boiler as previously described push and<br />
turn the fi lter cap in an anti-clockwise direction to release it<br />
from its housing.<br />
• Pull the cap out with the fi lter attached.<br />
1<br />
• Clean and replace as necessary refi lling and re-pressurising<br />
the boiler as required.<br />
18.7 Heating filter<br />
1 2<br />
Key<br />
1 Expansion vessel<br />
2 Expansion vessel pressure inlet<br />
• Check the expansion vessel's supply pressure (see «<br />
Technical Data » chapter) by means of the pressure inlet<br />
located on the expansion vessel. Adjust the pressure if<br />
necessary.<br />
3<br />
• Following the installation of a new expansion vessel, fi ll and<br />
purge the appliance or installation, if necessary.<br />
18.6 Plate heat exchanger filter<br />
BLUE<br />
1<br />
Key<br />
1 Filter<br />
2 Filter valve body<br />
3 Cap<br />
The fi lter valve located under the boiler at the right hand side<br />
prevents debris from entering the boiler. Should this become<br />
blocked<br />
2<br />
• shut off the Heating Flow and Return Filter Valve by turning<br />
the levers clockwise.<br />
• Drain the boiler from the drain cock behind the pump or by<br />
removing the cap "3" from the fi lter valve.<br />
3<br />
• Remove and clean the fi lter and refi t in reverse order, topping<br />
up the water pressure via the fi lling loop as required.<br />
Key<br />
1 Filter housing<br />
2 Filter<br />
3 Filter cap<br />