The Application Interface 269/315<br />

Additional explanations:<br />

1. The parameter bSrcSAPIdx specifies the service access point of the remote user that carries<br />

out this request and which data area should be updated by the abSDU. A bSrcSAPIdx value<br />

of 63 is not permitted. A value of 64 represents the NIL SAP.<br />

2. The parameter bSrvCls defines the FDL priority for the data transfer. Two priorities are<br />

possible:<br />

• <strong>PROFIBUS</strong>_DL_SERVICE_CLASS_LOW = 0 and<br />

• <strong>PROFIBUS</strong>_DL_SERVICE_CLASS_HIGH = 1.<br />

3. The parameter bTransmitStrategy specifies whether the update is transmitted only once<br />

or many times, in the case of "multiple" the data area is transferred again for each subsequent<br />

SRD service. This is done by choosing between<br />

• <strong>PROFIBUS</strong>_DL_REPLY_UPDATE_SINGLE = 0 and<br />

• <strong>PROFIBUS</strong>_DL_REPLY_UPDATE_MULTIPLE = 1<br />

<strong>PROFIBUS</strong> <strong>DP</strong>-<strong>Master</strong> |<br />

DOC061001API12EN | Revision 12 | English | 2010-12 | Released | Public © Hilscher, 2006-2010