Overview 80/315<br />

The length of the complete check configuration data block must not exceed 244 bytes, however, it is<br />

recommended not to exceed an amount of 32 bytes otherwise some restrictions apply, see the<br />

underlying IEC 61158 or EN 50170 specification.<br />

5.3.3.2 Identifier Byte for the General Format<br />

The identifier byte can be specified in the general (also called compact) format or the special format.<br />

In the general format, the meaning of the single bits is defined as follows:<br />

General Identifier Format of Identifier Byte<br />

(according to IEC 61158/EN 50170 Specification)<br />

Bit Name Value Description<br />

D7 Consistency Consistency extends over<br />

0 Byte or word (in case of D6 = 0)<br />

1 Whole length (in case of D6 = 1)<br />

D6 Length format Length format<br />

0 Byte structure<br />

1 Word structure<br />

D5 Output<br />

Input/Output/Special identifier format<br />

0 D4=0 This combination signifies the special<br />

identifier format, see below.<br />

D4=1 Input<br />

1 D4=0 Output<br />

D4=1 Input- Output<br />

D4 Input See above (D5). D5 and D4 are evaluated together.<br />

D3 Length of data 0 1 Byte/Word<br />

1<br />

…<br />

15 16 Bytes/Words<br />

(choice of byte or word depends on length format bit)<br />

Table 38: General Identifier Format of Identifier Byte according to IEC 61158/EN 50170 Specification<br />

Note: When transferring data in word mode, the high byte is transferred first by Profibus <strong>DP</strong>,<br />

then the low-byte. However, the Profibus <strong>DP</strong> <strong>Master</strong> has the possibility to swap this sequence<br />

of the bytes within the word, if required by the target system.<br />

5.3.3.3 Identifier Byte for the Special Format<br />

To allow extended configurations and to increase flexibility, a special extension of the identifier system<br />

described above is also supported by Profibus <strong>DP</strong>. The main advantages of this format are:<br />

• It is possible to determine the number of input and output bytes associated to the defined<br />

identifier.<br />

• User specific data can be added.<br />

<strong>PROFIBUS</strong> <strong>DP</strong>-<strong>Master</strong> |<br />

DOC061001API12EN | Revision 12 | English | 2010-12 | Released | Public © Hilscher, 2006-2010