Getting started / Configuration 56/315<br />

4.2.3 Detailed Description of Bus and <strong>Master</strong> Parameters<br />

Both the bus and the master need to be configured. The accurate choice of the bus parameters is the<br />

foundation of correctly operating data exchange on the Profibus network.<br />

The following table contains relevant information about the bus parameters (including the master’s<br />

parameters) for the <strong>PROFIBUS</strong> <strong>DP</strong>-<strong>Master</strong> firmware such as a short explanation of the meaning of the<br />

parameter and ranges of allowed values:<br />

Parameter Meaning Range of Value / Value<br />

Bus_Para_Len Contains the length of the Bus_Para including the field 34<br />

Bus_Para_Len itself<br />

FDL_Add Contains the own address of the <strong>PROFIBUS</strong> Device 1-125<br />

Baud_rate Contains the transmission speed 0-11<br />

T SL Slot-time 37-16383<br />

Min T SDR Min. station delay responder 1-1023<br />

Max T SDR Max. station delay responder 1-1023<br />

T QUI Quiet time 0-127<br />

T SET Setup time 1-255<br />

T TR Target rotation time >= 255<br />

G Gap update factor 1-255<br />

HSA Highest station address 1-126<br />

Max_Retry_Limit Retries if error occurs 1-15<br />

Bp_Flag See separate explanation below 0-255<br />

Min_Slave_Interval Minimum Slave Interval Time 0-65535<br />

Poll_Timeout Class2 Poll timeout 0-65535<br />

Data_Control_Time Data Control Time 1-65535<br />

Alarm_Max Maximum Alarms 7-32<br />

Max_User_Global_C<br />

ontrol<br />

Reserved<br />

<strong>Master</strong>_User_Data_L<br />

en<br />

<strong>Master</strong>_Class2_Nam<br />

e[32]<br />

<strong>Master</strong>_User_Data[32<br />

]<br />

T CL<br />

Max_T SH<br />

Maximum allowed parallel active USER Global Control<br />

Commands<br />

4 reserved octets<br />

1-255<br />

Contains the length of the USER <strong>Master</strong> data 0-32<br />

Name of the <strong>Master</strong> Class 2 (currently not used)<br />

USER specific Parameter data 0-32<br />

Isochronous cycle time<br />

Maximum Shift Time<br />

Table 25: Bus and <strong>Master</strong> Parameters, their Meanings and their Ranges of allowed Values<br />

<strong>PROFIBUS</strong> <strong>DP</strong>-<strong>Master</strong> |<br />

DOC061001API12EN | Revision 12 | English | 2010-12 | Released | Public © Hilscher, 2006-2010