Getting started / Configuration 57/315<br />

4.2.3.1 Bus_Para_Len<br />

This parameter is calculated as the length of the bus parameter structure in bytes including the field<br />

itself.<br />

4.2.3.2 FDL_Add<br />

This parameter is used for defining the address of the Profibus <strong>DP</strong> master itself.<br />

Note: Configuration of addresses in a Profibus network must be performed in such a way that<br />

all addresses are used uniquely. No addresses may appear twice or more often within the<br />

Profibus network!<br />

Note: Do not use the address 0 as the master address although this would both be possible<br />

and allowed because this address is often used by configuration and diagnosis devices.<br />

Therefore, it is a good idea to choose a non-zero address for the Profibus <strong>DP</strong> master.<br />

4.2.3.3 Baud_rate<br />

This parameter contains the baud rate (i.e. the transmission speed of data signals) used by all stations<br />

of the Profibus network in a coded manner. This value must be set to the same value at all slave<br />

stations within the network. If this is not the case, all stations with deviating transmission speed setting<br />

will not operate correctly.<br />

The coding is as follows:+<br />

Symbolic Name Baud rate Value<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_96 9,6 kBits/s 0<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_19_2 19,2 kBits/s 1<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_93_75 93,75 kBits/s 2<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_187_5 187,5 kBits/s 3<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_500 500 kBits/s 4<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_1500 1500 kBits/s 6<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_3000 3000 kBits/s 7<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_6000 6000 kBits/s 8<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_12000 12000kBits/s 9<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_31_25 31.25kBits/s 10<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_45_45 45.45 kBits/s 11<br />

<strong>PROFIBUS</strong>_DL_DATA_RATE_AUTO<br />

Table 26: Supported Baud Rates<br />

Auto-detection mode.<br />

This option is currently not<br />

supported.<br />

15<br />

<strong>PROFIBUS</strong> <strong>DP</strong>-<strong>Master</strong> |<br />

DOC061001API12EN | Revision 12 | English | 2010-12 | Released | Public © Hilscher, 2006-2010