11.01.2014 Views

PROFIBUS DP-Master

PROFIBUS DP-Master

PROFIBUS DP-Master

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Dual-Port-Memory 46/315<br />

In detail these bits have the following meaning:<br />

Error type<br />

MSK_<strong>PROFIBUS</strong>_APM_EXT_STA_CTRL_ERR<br />

Explanation<br />

CONTROL-ERROR:<br />

This error is caused by incorrect parameterization.<br />

MSK_<strong>PROFIBUS</strong>_APM_EXT_STA_ACLR_ERR<br />

AUTO-CLEAR-ERROR:<br />

The device stopped the communication to all slaves<br />

and reached the auto-clear end state<br />

MSK_<strong>PROFIBUS</strong>_APM_EXT_STA_NEXC_ERR<br />

NON-EXCHANGE-ERROR:<br />

At least one slave has not reached the data exchange<br />

state and no process data are exchanged with it.<br />

MSK_<strong>PROFIBUS</strong>_APM_EXT_STA_FATL_ERR<br />

MSK_<strong>PROFIBUS</strong>_APM_EXT_STA_NRDY<br />

MSK_<strong>PROFIBUS</strong>_APM_EXT_STA_TOUT<br />

Table 15: Error Types in Global Bits<br />

FATAL-ERROR:<br />

Because of a severe bus error, no bus communication<br />

is possible any more<br />

Host-NOT-READY-NOTIFICATION:<br />

Indicates if the host program has set its state to<br />

operative or not. If the bit is set the host program<br />

is not ready to communicate<br />

TIMEOUT-ERROR:<br />

The Device has detected an overstepped timeout<br />

supervision time because of rejected <strong>PROFIBUS</strong><br />

telegrams. It's an indication for bus short circuits while<br />

the master interrupts the communication. The number<br />

of detected timeouts are fixed in the Time_out_cnt<br />

variable. The bit will be set when the first timeout<br />

was detected and will not be deleted any more.<br />

• b<strong>DP</strong>M_state/ <strong>Master</strong> main state<br />

The master main state represents the operation mode of the Profibus <strong>DP</strong> master stack. This<br />

operation mode is defined in section<br />

6.1.3”<strong>PROFIBUS</strong>_FSPMM_CMD_SET_MODE_REQ/CNF – Set a new Operation Mode” of<br />

this document. Allowed operation modes are:<br />

Operation mode<br />

USIF_OFFLINE<br />

USIF_STOP<br />

USIF_CLEAR<br />

Value<br />

0x00<br />

0x40<br />

0x80<br />

USIF_OPERATE<br />

0xC0<br />

Table 16: Operation Modes of the Profibus <strong>DP</strong> <strong>Master</strong> and their Values<br />

Changes of the master main state are indicated by the<br />

<strong>PROFIBUS</strong>_FSPMM_CMD_MODE_CHANGE_IND – Mode changed Indication, also see<br />

section 0 for more information. If you want to change this state, you can accomplish this by<br />

sending a <strong>PROFIBUS</strong>_FSPMM_CMD_SET_MODE_REQ/CNF – Set a new Operation<br />

packet to the FSPMM task, also see section 6.1.3 of this document.<br />

<strong>PROFIBUS</strong> <strong>DP</strong>-<strong>Master</strong> |<br />

DOC061001API12EN | Revision 12 | English | 2010-12 | Released | Public © Hilscher, 2006-2010

Hooray! Your file is uploaded and ready to be published.