Form 5a - ICP Forests
Form 5a - ICP Forests
Form 5a - ICP Forests
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
The coded lists for vascular plants and cryptogams are available via the internet page of<br />
the responsible Expert Panel of <strong>ICP</strong> <strong>Forests</strong> (www.icp-forests.org/EPbiodiv.htm). In<br />
case that species will occur that are not included on this list, the National Focal Centre<br />
will take contact with the Expert Panel prior to the formal data submission to the<br />
European data centre. The Expert Panel will assign a new (999.999.999) code and<br />
include it on the list available on the internet. The new species will be submitted to the<br />
European data centre with the new code. An additional list of nationally important or<br />
problematic species can be prepared and maintained by the NFC if regarded necessary.<br />
(83) Cover of plant species<br />
(Chapter 8)<br />
Countries are free in the assessment of the abundance/cover of the plant species. The<br />
submission of this cover is done in % using up to 5 digits with a floating decimal<br />
separator (between 0.01, 99.99 and 100.0). In the DAR the complete assessment<br />
methods, as well as the adopted conversion to % shall be specified.<br />
(84) Other observations<br />
(Chapter 1, 2, 3a, 3b, 4, 5, 6, 7, 8, 9, 10a, 10b, 11)<br />
Any supplementary comments.<br />
(85) Description of instrument<br />
(Chapter 7)<br />
Text format<br />
(86) Quality information from the laboratory<br />
(Chapters 4, 6)<br />
Not longer valid:<br />
Laboratory ringtests are carried out under the responsibility of the Expert<br />
Panels/Working Groups of the <strong>ICP</strong> <strong>Forests</strong>. Expert Panels and the Programme<br />
Coordinating Centre of <strong>ICP</strong> <strong>Forests</strong> maintain lists with ringtest results per laboratory.<br />
These results can be linked to the data sets in the database. If there is no ringtest for the<br />
current year, the ringtest number from the previous test has to be used. If the laboratory<br />
did not participate in the most recent ringtest, a blanc shall be used.<br />
For all surveys with parameters which are measured at laboratories so called<br />
“Laboratory Quality Assurance” <strong>Form</strong>s (.LQA) are defined (s. section 4) and have to be<br />
submitted with the data of the respective survey.<br />
(87) Sample quantity<br />
(Chapter 6)<br />
In the DEM and DEO forms, the submission of with no analysis (e.g. no precipitation,<br />
no analytical results) should be distinguished from periods with missing data:<br />
Page 113 / 151