49<br />

e} At inlet screen (splinter shield) is available, however this accessory reduces the pumping speed of<br />

the TMP.<br />

3.24 - The bearings have been lubricated at the factory.<br />

3.3 - RECOMMENDED FORE PUMP<br />

3.31 - ALCATEL <strong>5101</strong> and <strong>5081</strong> TMP require a forepump. The ALCATEL 2004 A is recommended .. :" ."<br />

The selection of the forepump pumping speed will depend on the volume of the chamber to be pumped<br />

down and on the pump-down time to achieve 1.10- 2 mbar (this time must be 3 mn).<br />

3.32 - PRECAUTIONS<br />

To prevent oil backstreaming from the roughing pump (RP), avoid sudden changes in outlet circuit pressure.<br />

Optionally, in order to prevent oil vapor contamination of the TMP and chamber, the following can be<br />

connected between the TMP outlet and the RP :<br />

- a manual or automatic valve<br />

- a molecular sieve trap (the trap must not be exposed to the system)<br />

• the installation of a vent valve (NO) between the outlet flange of the TMP and the RP. (See chapt'f,6) ..<br />

3.33 - The forevacuum line must be constructed of flexible hose.<br />

- Remove protective cover from the TMP outlet.<br />

• Install a NW 25 (10 inches ID) flexible hose to the TMP outlet, with the other end connected to the<br />

roughing pump.<br />

3.34 - COOLING<br />

a) Air cooling device:<br />

The fan is assembled on the TMP by a bracket. This last is assembled on the pump rear tape with 3 screws<br />

CHc M4 x 10 (see figures 5/1 and 5/2).<br />

• Connect the fan to converter at J5 with the special cable.<br />

• The fan will start when the TMP is started.<br />

The fan provides sufficient cooling for ambient temperature up to 95° F. If the ambient temperature is above<br />

95° F, the user should install a water cooling collar.<br />

062794 • 1 0/1993