TYPICAL <strong>EL280UH</strong> FIELD WIRING DIAGRAM<br />

FIGURE 32<br />

TWO−STAGE INTEGRATED CONTROL<br />

1/4" QUICK CONNECT TERMINALS<br />

SENSE = 120 VAC OUTPUT TO FLAME SENSOR<br />

NEUTRALS= 120 VAC NEUTRAL<br />

DIAGNOSTIC<br />

LEDs<br />

PARK = DEAD TERMINAL FOR UNUSED BLOWER LEAD<br />

HEAT LOW = 120 VAC OUTPUT TO CIRC BLWR −− LOW HT SPEED<br />

HEAT HIGH/ COOL LOW = 120 VAC OUTPUT TO CIRC BLWR −−<br />

HIGH HEAT AND LOW COOL SPEED<br />

COOL HIGH = 120 VAC OUTPUT TO CIRC BLWR −− HIGH COOL SPEED<br />

THERMOSTAT CONNECTIONS (TB1)<br />

DIP<br />

SWITCHES<br />

ON−BOARD<br />

LINKS<br />

1= ERROR CODE RECALL<br />

H= 24V HUMIDIFIER OUTPUT<br />

L= LENNOX SYSTEM OPERATION MONITOR<br />

W915<br />

W951<br />

DIP SWITCH(ES)<br />

DIP SWITCH FUNCTIONS<br />

FUNCTION<br />

1 −− 2 <strong>Stage</strong> T’stat Selects t/stat type (single or two−stage)<br />

2 −− 2nd <strong>Stage</strong> Delay Second stage ON delay (single−stage t’stat)<br />

3 & 4 −− Heat Off Delay Heating fan OFF delay<br />

5 −− Cool Off Delay Cooling fan OFF delay<br />

FIGURE 33<br />