2. General<br />

2.1 Application / Inst<strong>all</strong>ation<br />

The Aqualift F <strong>Pumpstation</strong> is designed to automatic<strong>all</strong>y<br />

pump wastewater (with or without sewage collected below<br />

the outgoing sewer level) up to the sewer level so that it may<br />

flow with gravity out of the building and into a septic system<br />

/ public sewer piping. This system is only for use with wastewater<br />

draining from single and multi-family homes, commercial<br />

buildings, hotels, restaurants, hospitals, schools or<br />

similar buildings. In circumstances where the interruption of<br />

wastewater is not <strong>all</strong>owed or desired, a twin pump system<br />

(<strong>Pumpstation</strong> Aqualift F <strong>Duo</strong>) is required for inst<strong>all</strong>ation.<br />

The <strong>KESSEL</strong> <strong>Pumpstation</strong> Aqualift F is designed for outdoor<br />

underground inst<strong>all</strong>ation. Pumps are equipped with macerating<br />

blades which cut <strong>all</strong> soft objects into sm<strong>all</strong>er pumpable<br />

pieces. Due to the cutting blades, outlet pipes of DN 40<br />

or larger may be connected to the outlet of the <strong>Pumpstation</strong><br />

Aqualift F. Objects. The system is designed to handle a continuous<br />

inflow of wastewater up to 40 deg C (104 deg F).<br />

Options for the <strong>KESSEL</strong> <strong>Pumpstation</strong> Aqualift F include:<br />

• Single (1 pump) or Twin (2 pumps)<br />

• Pumps available with various power ratings<br />

• In <strong>KESSEL</strong> 800 or 1000mm diameter Inspection Chamber<br />

• Inst<strong>all</strong>ation depths from 1.5 to 5 meters.<br />

The pump support bases, closure valve, backflow prevention<br />

flap, outlet pressure pipe and float switches have already<br />

been inst<strong>all</strong>ed in the base of the chamber. The pump(s), additional<br />

chamber sections and the electrical control unit are<br />

shipped separately with the system. The pumps, depending<br />

on their size, are shipped either in the chamber upper section<br />

or on a separate p<strong>all</strong>et. The pumps are to be inst<strong>all</strong>ed<br />

only after the complete chamber has been completely assembled<br />

and inst<strong>all</strong>ed. In order to prevent the build up of dangerous<br />

gases in the chamber which can cause an explosion<br />

risk, the system must be ventilated appropriately.<br />

2.2 Aqualift F description<br />

The <strong>KESSEL</strong> <strong>Pumpstation</strong> Aqualift F in single or twin pump<br />

variations is comprised of the following systems.<br />

1. Single or double sewage pumps with cutting assembly<br />

2. <strong>KESSEL</strong> Inspection Chamber 800 or 1000<br />

(mm diameter)<br />

3. Curve pump support base<br />

4. Closure valve for each pump<br />

5. Backflow prevention flap<br />

6. Pressure pipe outlet connection PN 10 from<br />

PEHD DN 50 (Outside Diameter – 63 mm or DN 80<br />

(Outside Diameter – 90 mm)<br />

7. Connection for ventilation pipe (DN 100)<br />

8. Connection for power / control cables (DN 100)<br />

9. Connection for inlet DN 100/150<br />

10. Float switch<br />

11. Electrical control unit (See Chapter 8)<br />

8<br />

7<br />

9<br />

2<br />

4<br />

6<br />

5<br />

1<br />

3<br />

10<br />

Illustration shows <strong>KESSEL</strong> <strong>Pumpstation</strong> Aqualift F<br />

twin pumping unit<br />

6