4. Un-install all eventual installed TFR patches:<br />

setld -D /usr/opt/TeMIP -f -d TFRPATCHXXXXV500XXXX<br />

setld -D /usr/opt/TeMIP -f -d TFRTRU64XXXX (new name for<br />

TFR patches on Tru64)<br />

The error message:<br />

“ERROR: TeMIP Subsets cannot be installed in<br />

Use the -D option with a path of the form: /usr/opt/TeMIP<br />

where is a string of your choice.<br />

Setld: TFRPATCHXXXXV500XXXX deletion declined by subset<br />

control program,<br />

But subset will be deleted anyway on member1.”<br />

indicates a well-known problem described in TruCluster documentation (see<br />

OpenView TeMIP Use in a TruCluster Environment/Subset Un-installation<br />

section)<br />

5. Un-install TFRXXXXV50001P003 maintenance patch subsets:<br />

setld -D /usr/opt/TeMIP -d TFRXXXXV50001P003<br />

6. Execute the mandatory pre-installation operations: see section 3.3.3.1.<br />

7. Install the STM and Orbix pre-requisite subsets and the TeMIP Framework<br />

V5.0 Patch 4 for Tru64 subsets under this new release tree (see Section 3.3).<br />

(The warning message indicates that the temip_activate is not performed, as the<br />

TeMIP Framework V5.0 Patch 4 for Tru64 is not installed on the active release<br />

tree)<br />

8. Execute the mandatory post-installation operations: see section 3.3.3.2.<br />

9. Generate a new CAA action script for the TeMIP director if needed or reset<br />

correct values in the existing one (see Sections 3.2.2.2 and 3.2.2.3).<br />

10. Activate this new release tree (see Section 3.2.2.4)<br />

11. Configure the TAL Orbix Server FM and the TeMIP MAP (if needed). (see<br />

section 3.4)<br />

12. Restart the TeMIP director (caa_start )<br />

3.3 Installing the TFRV50001-04 Subsets<br />

Be sure to observe all the points listed in the TeMIP Framework V5.0 Patch 4 for<br />

Tru64 Compatibility section (see Chapter 2).<br />

You can only install the TeMIP Framework V5.0 Patch 4 for Tru64 subsets if the<br />

corresponding Manufacturing Release subsets have already been installed on the<br />

system.<br />

You must first install pre-requisite subsets (see Section 3.3.1). Then you can choose<br />

to install the maintenance patch manually using setld command (see Section 3.3.3) or<br />

using TeMIP SystemMate tool (see Section 3.3.2)<br />

The following list shows the subsets delivered with the TFRV50001-04 Maintenance<br />

Patch kit:<br />

Subset<br />

TFRBASEV50001P004<br />

Description<br />

TeMIP Framework Base System Release<br />

V500 level 01 patch 004 Rev E<br />

17