4. Un-install all eventual installed TFR patches:<br />
setld -D /usr/opt/TeMIP -f -d TFRPATCHXXXXV500XXXX<br />
setld -D /usr/opt/TeMIP -f -d TFRTRU64XXXX (new name for<br />
TFR patches on Tru64)<br />
The error message:<br />
“ERROR: TeMIP Subsets cannot be installed in<br />
Use the -D option with a path of the form: /usr/opt/TeMIP<br />
where is a string of your choice.<br />
Setld: TFRPATCHXXXXV500XXXX deletion declined by subset<br />
control program,<br />
But subset will be deleted anyway on member1.”<br />
indicates a well-known problem described in TruCluster documentation (see<br />
OpenView TeMIP Use in a TruCluster Environment/Subset Un-installation<br />
section)<br />
5. Un-install TFRXXXXV50001P003 maintenance patch subsets:<br />
setld -D /usr/opt/TeMIP -d TFRXXXXV50001P003<br />
6. Execute the mandatory pre-installation operations: see section 3.3.3.1.<br />
7. Install the STM and Orbix pre-requisite subsets and the TeMIP Framework<br />
V5.0 Patch 4 for Tru64 subsets under this new release tree (see Section 3.3).<br />
(The warning message indicates that the temip_activate is not performed, as the<br />
TeMIP Framework V5.0 Patch 4 for Tru64 is not installed on the active release<br />
tree)<br />
8. Execute the mandatory post-installation operations: see section 3.3.3.2.<br />
9. Generate a new CAA action script for the TeMIP director if needed or reset<br />
correct values in the existing one (see Sections 3.2.2.2 and 3.2.2.3).<br />
10. Activate this new release tree (see Section 3.2.2.4)<br />
11. Configure the TAL Orbix Server FM and the TeMIP MAP (if needed). (see<br />
section 3.4)<br />
12. Restart the TeMIP director (caa_start )<br />
3.3 Installing the TFRV50001-04 Subsets<br />
Be sure to observe all the points listed in the TeMIP Framework V5.0 Patch 4 for<br />
Tru64 Compatibility section (see Chapter 2).<br />
You can only install the TeMIP Framework V5.0 Patch 4 for Tru64 subsets if the<br />
corresponding Manufacturing Release subsets have already been installed on the<br />
system.<br />
You must first install pre-requisite subsets (see Section 3.3.1). Then you can choose<br />
to install the maintenance patch manually using setld command (see Section 3.3.3) or<br />
using TeMIP SystemMate tool (see Section 3.3.2)<br />
The following list shows the subsets delivered with the TFRV50001-04 Maintenance<br />
Patch kit:<br />
Subset<br />
TFRBASEV50001P004<br />
Description<br />
TeMIP Framework Base System Release<br />
V500 level 01 patch 004 Rev E<br />
17