Ref Component Description Workaround<br />

AS SELECT * FROM<br />

temipmap.MAP_ITEMS@master92.nieves.vbe.cpqcorp.net<br />

*<br />

ERROR at line 5:<br />

ORA-01753: column definition incompatible with clustered column definition<br />

Master 9.2 -> Replica 9.1<br />

But, no problem has been detected<br />

for configurations:<br />

Master 9.2 -> Replica 9.2<br />

Master 9.1 -> Replica 9.1<br />

Master 9.1 -> Replica 9.2<br />

18778 GAT TRU64: Issue with function strptime() in V5.1B PatchKit 2 BL 22.<br />

The AXE10 is disrupted in its alarm decoding, when calling the function:<br />

strptime().<br />

The function is called in the GAT (BinAbsTime.cxx).<br />

(Actually, the AXE10 doesn't crash, and still provide an alarm, but this alarm<br />

doesn't correspond to the alarm provided by the equipment => the severity is set<br />

to INDETERMINATE, the timestamp, is the current one).<br />

The problem is that before the PatchKit 2 BL22, the strptime() function was<br />

accepting white space in the "date" input string.<br />

Since PatchKit 2 BL22, the strptime() returns a null pointer, if the input "date"<br />

contains spaces, and thus doesn't match strictly, the input format.<br />

A case is open to Tru64 concerning<br />

this issue.<br />