Detailed set-up (continued)<br />
Parameters in bold can be changed / edited.<br />
Trigger<br />
level<br />
Process<br />
variable<br />
Event<br />
notification<br />
control<br />
Event<br />
notification<br />
re-try time<br />
Maximum<br />
update time<br />
Event<br />
debounce<br />
interval<br />
Device<br />
status<br />
mask<br />
Ext dev<br />
status<br />
mask<br />
The level at which a transmission is<br />
triggered.<br />
Available if cmd 9 or cmd 33 is<br />
selected. Enables the user to map the<br />
device variables onto the process /<br />
burst variables.<br />
Enables the device to notify the<br />
gateway of changes in condition and<br />
status. The time of the change is also<br />
send by the device.<br />
The time the device will continuously<br />
re-send the notification of the event<br />
until an acknowledgement has been<br />
received.<br />
If an event or condition has not<br />
occurred <strong>with</strong>in this time period, then<br />
the device will automatically send an<br />
event notification to the gateway. This<br />
period should be equal or greater than<br />
event notification re-try time. Occurs<br />
only once.<br />
The time an event or a condition<br />
must be present, be<strong>for</strong>e notification<br />
is sent. This prevents spurious event<br />
notifications.<br />
Enables the status flags to trigger and<br />
event notification<br />
• More status Available: More<br />
operational in<strong>for</strong>mation is available<br />
• Cold start: Power failure or device<br />
reset has occurred<br />
• Configuration Changed. The device<br />
has been re-configured<br />
• Field Device Malfunction. The device<br />
has detected a serious problem.<br />
• Maintenance required: Not used.<br />
• Device variable alert: Not used.<br />
• Critical Power failure: Not used.<br />
- 0<br />
Various, see<br />
device variables<br />
Off or Enable<br />
event notification<br />
on TDMA data<br />
link layer<br />
0.1, 0.25, 0.5, 1,<br />
2, 4, 8, 16, 32, 60<br />
to 3600 seconds<br />
0.1, 0.25, 0.5, 1,<br />
2, 4, 8, 16, 32, 60<br />
to 3600 seconds<br />
0.1, 0.25, 0.5, 1,<br />
2, 4, 8, 16, 32, 60<br />
to 3600 seconds<br />
total<br />
Off<br />
32 seconds<br />
60 seconds<br />
4 seconds<br />
- Unmasked<br />
- Unmasked<br />
46<br />
IM-P337-62 MI Issue 1