ARCTIC COMPACT & DELUXE<br />

6 ROUTINE MAINTENANCE<br />

1 Replacement of lighted top cover bulbs (see figure 9) :<br />

- Remove the fixing screws placed in the upper part of the top<br />

cover,<br />

- remove the lower part and replace the bulbs (using a 24-<br />

28V 21W max bulbs).<br />

- Reassemble the top cover and replace the fixing screws.<br />

figure 9<br />

2 Daily: inspect the machine for signs of product leaks past<br />

seals and gaskets. If proper assembly does not stop leaks<br />

around seals or gaskets, check for improper lubrication, worn<br />

or damaged parts. Replace parts as needed with original spare<br />

parts from the supplier.<br />

6. 1 MAINTENANCE (TO BE CARRIED OUT BY<br />

QUALIFIED SERVICE PERSONNEL ONLY)<br />

Montly: clean all internal components, primarily the condenser,<br />

using compressed air.<br />

To clean these internal parts, unplug the unit or switch off the 2-<br />

pole wall breaker, then remove front panel (dispensing side).<br />

Condenser fins are very sharp. Use extreme caution when<br />

cleaning.<br />