MARQUIS Newberg<br />

33 41 00 STORM UTILITY DRAINAGE PIPING<br />

October 5, 2012<br />

F. Polyvinyl Chloride Pipe: ASTM D2729; plain end, inside diameter as shown on drawings, with<br />

required fittings.<br />

G. Corrugated Plastic Tubing: Flexible type; inside diameter as shown on drawings, with required<br />

fittings.<br />

H. Backwater Valve: Rectorseal Clean Check ® or approved equal<br />

2.2 BEDDING AND COVER MATERIALS<br />

A. Bedding: Fill Type as specified in Section 31 05 13.<br />

B. Cover: Fill Type as specified in Section 31 05 13.<br />

C. Subdrainage pervious Fill Materials: 1 ¼ ” – ¼” clean drain rock.<br />

2.3 RIPRAP MATERIALS<br />

A. Furnish materials in accordance with OSSC standards<br />

B. Riprap: Broken stone Irregular shaped rock size as shown on drawings.<br />

2.4 ACCESSORIES<br />

A. Geotextile Fabric: Non-biodegradable, woven & non-woven.<br />

1. AMOCO, Mirafi or approved equal<br />

B. Fittings: Same material as pipe molded or formed to suit pipe size and end design, in required tee,<br />

bends, elbows, clean-outs, reducers, traps and other configurations required.<br />

C. Trace Wire: Magnetic detectable conductor, clear, brightly colored plastic covering, imprinted with<br />

"Storm Sewer Service" in large letters. Brimar or approved equal<br />

2.5 CATCH BASINS, TRENCH DRAINS AND AREA DRAINS<br />

A. Parking Lot Trapped Inlets: Square as indicated on the Drawings, Lynch style catch basin. Gibson<br />

Steel or approved equal<br />

1. H20 Load rated, 10 guage asphalt dipped steel.<br />

2. Lid design: Square, bike proof linear grill.<br />

3. Nominal lid and frame size: as shown on drawings.<br />

B. Area Drain: Square as indicated on the Drawings. Gibson Steel or approved equal.<br />

1. 10 ga. asphalt dipped steel, adapted for ADA grate where shown on drawings.<br />

2. Lid design: square bar, or ADA grate<br />

3. Nominal lid and frame size: as shown on drawings<br />

C. Trench Drain: As indicated on the drawings, H20 load rated<br />

1. ACO Drain Klassik Drain or approved equal.<br />

a. Grate: Shall be Ductile Iron, meeting ADA requirements, ACO Drain - Mosaic Iron<br />

or approved equal.<br />

b. Catch Basin: ACO Drain K900 with trash bucket or approved equal.<br />

2.6 CLEANOUTS<br />

A. Cleanout Lid and Frame: Cast iron construction, as indicated on drawings.<br />

1. Lid Design: Standard cast iron frame and cover.<br />

33 41 00 STORM UTILITY DRAINAGE PIPING<br />