<strong>TK</strong>-<strong>880</strong>/H<br />

ADJUSTMENT<br />

Item<br />

Condition<br />

Measurement<br />

Testequipment<br />

Unit Terminal<br />

Adjustment<br />

Unit Parts Method<br />

6. Modulation 1) Set test mode Power meter Rear ANT Make the de- (Wide/Narrow)<br />

balanced MIC input : OFF Deviation panel modulation<br />

Select “BAL” in tuning mode. meter<br />

waveform neat.<br />

“L BAL” Oscilloscope<br />

Deviation meter filter<br />

LPF : 15kHz AF VTVM Front MIC<br />

HPF : OFF AG panel<br />

De-emphasis : OFF<br />

2) “C BAL”<br />

PTT : ON<br />

3) “H BAL”<br />

PTT : ON<br />

Specifications/Remarks<br />

7. Maximum 1) Set test mode 3.8kHz (Wide) ± 50Hz (Wide/Narrow)<br />

deviation Connect AG to the MIC 1.75kHz (Narrow)<br />

terminal.<br />

(According to the<br />

Select “MAX” in tuning mode. larger +, –)<br />

“L MAX”<br />

AG : 1kHz/50mV<br />

Deviation meter filter<br />

LPF : 15kHz<br />

HPF : OFF<br />

De-emphasis : OFF<br />

PTT : ON<br />

2) “C MAX”<br />

PTT : ON<br />

3) “H MAX”<br />

PTT : ON<br />

8. MIC 1) Set test mode Check ± 3kHz± 0.2kHz (Wide)<br />

seisitivity CH : CH1 - Sig1 ± 1.5kHz± 0.05kHz (Narrow)<br />

check AG : 1kHz/5mV<br />

PTT : ON<br />

9. QT deviation 1) Set test mode 0.75kHz (Wide) ± 50Hz (Wide/Narrow)<br />

Select “FQT” in tuning mode.<br />

0.35kHz (Narrow)<br />

“L FQT”<br />

Deviation meter filter<br />

LPF : 3kHz<br />

HPF : OFF<br />

PTT : ON<br />

2) “C FQT”<br />

PTT : ON<br />

3) “H FQT”<br />

PTT : ON<br />

10. DQT 1) Set test mode 0.75kHz (Wide) ± 50Hz (Wide/Narrow)<br />

deviation Select “F DQT” in tuning mode. 0.35kHz (Narrow)<br />

“L FDQT”<br />

Deviation meter filter<br />

LPF : 3kHz<br />

HPF : OFF<br />

PTT : ON<br />

2) “C FDQT”<br />

PTT : ON<br />

3) “H FDQT”<br />

PTT : ON<br />

56