<strong>HF</strong> <strong>MIFARE</strong> <strong>Easy</strong> <strong>Module</strong><br />

User Manual, Firmware V1.0<br />

1506-USM-01-0-03<br />

4.3.4 Protocol configuration (05h)<br />

The protocol configuration register (PCON) specifies general behavior of the reader device.<br />

Default value is 01h.<br />

Protocol configuration register<br />

Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0<br />

RFU RFU RFU Multitag Binary<br />

Timeout<br />

Extend ID Binary Auto Start<br />

Figure 4-4: Protocol configuration register<br />

4.3.4.1 Autostart (default 1)<br />

If set the reader device will start up in continuous read mode automatically.<br />

4.3.4.2 Protocol (default 0)<br />

If set the reader uses binary protocol mode. Refer to binary protocol for further information on the<br />

binary protocol format.<br />

Default setting = ASCII protocol (0).<br />

Extended ID (default 0)<br />

This setting does only affect the commands continuous reading (‘c’), select (‘s’) and multi tag<br />

select (‘m’).<br />

If set a the unique serial number of the transponder is extended by a single prefix byte.<br />

The values for the prefix byte are:<br />

prefix<br />

01h<br />

02h<br />

03h<br />

04h<br />

05h<br />

06h<br />

FFh<br />

description<br />

<strong>MIFARE</strong> ® Light Transponder<br />

<strong>MIFARE</strong> ® Standard Transponder<br />

<strong>MIFARE</strong> ® 4k Transponder<br />

<strong>MIFARE</strong> ® ProX Transponder<br />

<strong>MIFARE</strong> ® UltraLight Transponder<br />

<strong>MIFARE</strong> ® DESFire Transponder<br />

Unknown Transponder<br />

4.3.4.3 Binary Timeout (default 0)<br />

This flag is only interpreted if the reader operates in binary mode.<br />

If the serial bus stays idle for more than 96 ms (no data is transmitted), the reader will clear its<br />

command buffer and enter “Command Read” mode.<br />

The “Command Read” mode means that the reader is waiting for valid data frames (beginning<br />

with the STX code).<br />

November 4, 2008 Page 25 of 63<br />

© 2008 HID Global Corporation. All rights reserved.