<strong>HF</strong> <strong>MIFARE</strong> <strong>Easy</strong> <strong>Module</strong><br />

User Manual, Firmware V1.0<br />

1506-USM-01-0-03<br />

4.4.3.11 Read reader EEPROM<br />

This command reads the internal reader EEPROM. It contains all startup parameters and the<br />

device ID. Changes of the startup settings will only be taken into effect after a reset of the device.<br />

Command<br />

Command<br />

're'<br />

Data<br />

EEPROM address (1 byte) 00h … 13h<br />

Answer<br />

Answer<br />

Data<br />

Description<br />

EEPROM data (1 byte)<br />

Example<br />

Command<br />

rp05<br />

Description<br />

Reads protocol configuration register.<br />

4.4.3.12 Read value block<br />

Reads a value block. The command checks if data is in value block format. The read value block<br />

command needs a successful login.<br />

Command<br />

Command<br />

'rv'<br />

Data<br />

Value block (1 byte)<br />

Answer<br />

Answer<br />

Data<br />

'F'<br />

'I'<br />

'N'<br />

Description<br />

Read value (4 bytes)<br />

Error: General failure<br />

Error: value block failure<br />

Error: No tag in field<br />

Example<br />

Command<br />

Description<br />

rv04 Reads value of block 4.<br />

4.4.3.12.1 No value block 'I'<br />

The value read back after the write value instruction is a not a value block. Data was written<br />

corruptly.<br />

4.4.3.12.2 No tag error 'N'<br />

This means that the tag does not respond, because there is either no tag present or none of the<br />

tags in the field is authenticated ('l' instruction).<br />

4.4.3.12.3 General failure 'F'<br />

Additional to a data read error caused by bad transmission conditions, this error appears if a<br />

sector is addressed which is not located in the authenticated sector.<br />