<strong>HF</strong> <strong>MIFARE</strong> <strong>Easy</strong> <strong>Module</strong><br />

User Manual, Firmware V1.0<br />

1506-USM-01-0-03<br />

4.4.3.17.1 Writing master keys<br />

Keys are write only. It is not possible to read the keys. Nevertheless the reader returns correct<br />

error messages if the writing process fails.<br />

A verification of the master key can only be done using an appropriate card and a successful<br />

login.<br />

4.4.3.17.2 Using master keys for authentication<br />

Master keys may be used for ISO-14443 A tag authentication. It is possible to use every stored for<br />

key A as well as key B authentication.<br />

Each key is 6 bytes long and stored redundantly for data security.<br />

4.4.3.18 Write value block<br />

This command formats a block as a value block containing a 32-bit value. A read after write is<br />

performed automatically. Value blocks need a complete 16-byte block due to redundant storage. A<br />

successful login is required to run the command.<br />

Command<br />

Command<br />

'wv'<br />

Data<br />

Value block (1 byte)<br />

Value (4 bytes)<br />

Answer<br />

Answer<br />

Data<br />

'I'<br />

'F'<br />

'N'<br />

'U'<br />

Description<br />

Written value (4 bytes)<br />

Error: value block failure<br />

Error: increment failure<br />

Error: No tag in field<br />

Error: Read after write failure<br />

Example<br />

Command Description<br />

wv05010055EF Writes value 010055EFh to block 5.<br />

4.4.3.18.1 Invalid value 'I'<br />

The value read back after the write value instruction is a not a value block. Data was written<br />

corruptly.<br />

4.4.3.18.2 Write failure 'F'<br />

Additional to a data read error caused by bad transmission conditions; this error appears if a<br />

sector is addressed which is not located in the authenticated sector.<br />

4.4.3.18.3 No tag error 'N'<br />

This error is returned if no tag is present or the card does not respond.<br />

November 4, 2008 Page 43 of 63<br />