Overview<br />

Overview of the instrument families<br />

<strong>Camille</strong> <strong>Bauer</strong><br />

Multifunctional Transducers, Overview<br />

SINEAX M56x SINEAX DME4 SINEAX CAM<br />

Measuring system<br />

Sampling values per system period 24 32 128 (continuously)<br />

Accuracy class<br />

0.5<br />

Analogue outputs: 0.25<br />

Measured variables of bus: 0.2<br />

Basic instrument: 0.2<br />

I/O modules: 0.1<br />

Setting time (at 50 Hz) ≥ 1.0s, depending on the system ≥ 0.3s, depending on the system<br />

configuration and the selected configuration and the selected<br />

≥ 0.06s<br />

measured variables<br />

measured variables<br />

Nominal frequency 50/60 Hz 16.7 Hz, 50/60 Hz 45…65 Hz, 10…70 Hz, 10…140 Hz<br />

Nominal <strong>current</strong> 1…6 A 1…6 A 1…5 A, Overriding up to 10 A<br />

Nominal voltage 57.7…400 V (Ph–N)<br />

57.7…400 V (Ph–N)<br />

57…400 V (Ph–N)<br />

Measured variables<br />

100…693 V (Ph–Ph)<br />

100…693 V (Ph–Ph)<br />

100..693 V (P–P)<br />

Basic variables of the system 1 • • •<br />

Neutral wire <strong>current</strong> measurement •<br />

Meters • •<br />

Tariff switching for meters •<br />

Unbalance •<br />

THD, TDD, harmonics Up to the 50th harmonic<br />

Maximum and minimum value<br />

with time stamp<br />

•<br />

Mean value acquisition •<br />

Logger for measured value<br />

progression<br />

Option<br />

Alarm / event / operator lists Option<br />

Display of measured values and<br />

lists, acknowledgement of alarms<br />

Measured values + meters with<br />

accessory SINEAX A200<br />

Option (internal or external)<br />

I/O interface fixed fixed modular (up to 4 modules)<br />

Analogue outputs 1, 2 or 3 2 or 4 2 per module<br />

Analogue inputs 2 per module<br />

Digital outputs 4 or 2 3 per module<br />

Digital inputs 3 per module<br />

HV input 110/230 VAC 1 per module<br />

Possible bus connections<br />

Special software functions<br />

RS485 (Modbus), Profibus, LON As a standard:<br />

RS485 (Modbus) + USB<br />

Option: Ethernet IEC 61850 or<br />

Modbus/TCP<br />

System check • •<br />

Check of connection •<br />

Logic module •<br />

1 The basic variables of the system are all single and system variables of voltage, <strong>current</strong>, bimetal <strong>current</strong>, active, reactive and apparent power,<br />

reactive and power factor as well as frequency<br />

19