Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Analogue Signal Processing<br />

Weidmüller interface units<br />

2-way isolation separates the signals and decouples the measuring circuits.<br />

Potential differences, caused by long line leads and joint reference<br />

points, are eliminated. Signal isolation also protects from destruction by<br />

overvoltage together with inductive and capacitive gaps.<br />

3-way isolation also separates the supply voltage to the input and output<br />

circuit and allows for operation with only one operating voltage.<br />

Passive isolators have another crucial advantage: they do not need any<br />

additional power supply. The power supply for the module comes from the<br />

input or output circuit and is transferred to the input/output. The outstanding<br />

feature of this current loop feed is its very low own consumption.<br />

There is a wide range of products for measuring temperature. PT100 signals<br />

are converted in 2, 3 and 4-conductor system to standardised signals<br />

0-20 mA, 4-20 mA and 0-10 V.<br />

The modules for connecting to commercially available thermocouples<br />

have cold joint compensation as a standard feature. In addition, they<br />

amplify and linearise the voltage signal issued by the thermocouple. This<br />

guarantees exact conditioning of the analogue signal, eliminating interference<br />

or fault sources.<br />

Frequency converters convert frequency into analogue standard signals<br />

so that subsequent controllers can directly process pulse sequences for<br />

speed or velocity measurement.<br />

No kind of automation is conceivable without AD or DA converters. To<br />

bring together the analogue signals which portray the environment with<br />

the digital processing of the process monitoring system, analogue signals<br />

have to be converted into digital ones. Weidmüller also offers these modules<br />

for the common input and output signals 0 … 20 mA, 4 … 20 mA<br />

and 0 … 10 V, with 8 bit or 12 bit available on the digital side. All modules<br />

have an additional input for freezing the current measured value.<br />

Current monitoring modules control the current values up to 60 A for<br />

dc or ac current. If the values fall below or above the setting, then the<br />

switch output is triggered. Modules with analogue outputs monitor the<br />

current flow continuously using subsequent controllers.<br />

Voltage monitoring modules are used to monitor dc and ac voltage.<br />

The freely adjustable switching threshold can be used to detect and report<br />

fluctuations in voltage as a result of switching procedures or mains overload.<br />

Analogue Signal Processing<br />