PLC Interface<br />
PLC system interface<br />
Interface units<br />
G<br />
Wiring and circuitry is becoming increasingly<br />
complicated as a result of the growing<br />
complexity of machines and systems<br />
in process, automation and building services<br />
control systems. Conventional connection<br />
(point-to-point wiring) of PLC<br />
controllers to the peripheral devices<br />
results in high installation and commissioning<br />
costs. The family of PLC system<br />
interface products provides the user with<br />
a quickly and easily installed output level<br />
for SIEMENS SIMATIC ® S7.<br />
The specific front adapters replace the<br />
usual screw terminal technology used on<br />
the PLC input/output cards. 40 or 10<br />
pole connectors transfer the PLC signals<br />
to the active or passive components via<br />
preassembled control leads.<br />
The PLC signals are converted either<br />
• in double word mode to a 40-pole<br />
ribbon cable connector<br />
or<br />
• in byte mode to 4 ribbon cable<br />
connectors each with 10 poles.<br />
Individual wiring<br />
PLC I/O cards usually have two connection<br />
systems:<br />
• screw clamp<br />
• crimp connectors.<br />
In both cases, the signals have to be<br />
wired individually with the corresponding<br />
connection elements.<br />
Disadvantages of individual wiring:<br />
• High assembly costs<br />
• The risk of wiring mistakes increases<br />
with the number of individual wires at<br />
one point<br />
• Takes up a lot of space in the switchboard<br />
• High installation workload<br />
• A lot of time spent on routing and<br />
assembly of connecting leads<br />
• High labelling and documentation<br />
workload.<br />
PLC<br />
System wiring<br />
The basic principle is the connection of<br />
PLC-specific front adapters to passive<br />
and active input/output modules using<br />
preassembled leads. The PLC adapters<br />
are plugged directly to the I/O cards.<br />
Within the adapters, the PLC-specific<br />
connection level is adapted to ribbon<br />
cable plug connectors to IEC 603-1/<br />
DIN 41651. The passive and active<br />
input/output modules can therefore be<br />
used regardless of the corresponding<br />
controller type.<br />
There are two possible connection<br />
versions:<br />
• in double word mode to a 40-pole<br />
ribbon cable connector<br />
or<br />
• in byte mode to 4 ribbon cable<br />
connectors each with 10 poles.<br />
System wiring offers the following<br />
advantages over point-to-point wiring:<br />
• Minimum wiring workload<br />
• Reduced installation times<br />
• Simplified commissioning and<br />
documentation.<br />
The product series of PLC system interface<br />
modules offers a quickly and easily<br />
installed input and output level for<br />
SIEMENS SIMATIC ® S7.<br />
PLC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />