Overvoltage protection for energy distribution systems<br />
Overvoltage protection<br />
I<br />
Class I with triggered spark gap<br />
Class I lightning arrester<br />
Technical data<br />
Technical specification<br />
Rated voltage Un (AC)<br />
Operating voltage Uc (ac), max.<br />
Requirement class acc. to IEC 61643-1<br />
lightening test voltage imp (10/350µs)<br />
Specific energy, per path<br />
Short-circuit current extinction without back-up fuse<br />
Short-circuit strength at max. back-up fuse<br />
Response time<br />
Back-up fuse, max.<br />
Protection level Up (typ.)<br />
Optical function indicator<br />
Colour<br />
Oper. temp. min./Oper. temp. max.<br />
Stor. temp. min./Storage temp., max.<br />
Approvals le E198315<br />
Dimensions<br />
Clamping range (rating- / min. / max.) mm 2<br />
Length x width x height<br />
mm<br />
Information<br />
Ordering data<br />
Version<br />
PU 1 TSG 35kA/0.9kV-260V<br />
for use in building networks<br />
Technical specification<br />
230Vac voltage Un (AC)<br />
L / N<br />
260V ating voltage Uc (ac), max.<br />
Trigger<br />
class I ment class acc. to IEC 61643-1<br />
35 kA by charging 17.5As imp (10/350µs)<br />
305kJ/M rgy, per path<br />
3 kA / 50 Hz t current extinction without back-up fuse<br />
25 kAeff rcuit strength at max. back-up fuse<br />
< 1 µs time<br />
125 A gl fuse, max.<br />
0.90kV tion level Up (typ.)<br />
LED green unction indicator<br />
grey ur<br />
-40°C/85°C . min./Oper. temp. max.<br />
-40°C/85°C . min./Storage temp., max.<br />
cURus, File E198315<br />
KEMA<br />
35 / 10 / 35<br />
91 x 18.0 x 63<br />
Type Qty. Order No.<br />
PU 1 TSG 35kA / 0,9kV 1 8561260000<br />
PU 1 TSG 50kA/1.5kV-260V<br />
for use in building networks<br />
Technical specification<br />
230Vac voltage Un (AC)<br />
L / N<br />
260V ating voltage Uc (ac), max.<br />
Trigger<br />
class I ment class acc. to IEC 61643-1<br />
50 kA by charging 25As imp (10/350µs)<br />
625kJ/M rgy, per path<br />
500 A / 50 Hz current extinction without back-up fuse<br />
25 kAeff rcuit strength at max. back-up fuse<br />
< 1 µs time<br />
125 A gl fuse, max.<br />
1.50kV tion level Up (typ.)<br />
Optical function indicator<br />
grey ur<br />
-40°C/85°C . min./Oper. temp. max.<br />
-40°C/85°C . min./Storage temp., max.<br />
cURus, File E198315<br />
KEMA<br />
35 / 10 / 35<br />
91 x 18.0 x 63<br />
Type Qty. Order No.<br />
PU 1 TSG 50kA / 1,5kV 1 8561230000<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Information<br />
Cross-connection QB 18-4 order no. 8619440000<br />
Cross-connection QB 18-6 order-no.8619450000<br />
Cross-connection QB 18-4 order no. 8619440000<br />
Cross-connection QB 18-6 order no. 8619450000<br />
Accessories<br />
Information<br />
Designation<br />
BZ18, L1 L2 L3 N PE order no. 8619460000<br />
Designation<br />
BZ18, PE PE PE PE PE Order No. 8619470000<br />
I.4<br />
Articles with coloured order number are kept permanently in stock at the central warehouse in Germany.<br />
Delivery times see page X.2