18.07.2014 Views

NetIQ Access Manager Appliance 3.2 SP2 Event Codes

NetIQ Access Manager Appliance 3.2 SP2 Event Codes

NetIQ Access Manager Appliance 3.2 SP2 Event Codes

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Event</strong> Code Description Remedy<br />

100903005 Error in the ResponseHandler thread of<br />

the DelayedResponseListener.<br />

Cause: Error occurred while processing a<br />

response.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

100903006 Error creating XML Element in<br />

ResponseBuilder.<br />

100903007 Error waiting on mutex in<br />

RequestDispatcher.<br />

Cause: Error occurred while editing XML.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

Cause: Error occurred while getting<br />

responses.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

100903008 Error notifying mutex in<br />

RequestDispatcher.<br />

Cause: Error occurred while receiving a<br />

response.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

100903009 Error receiving in SendInternal of<br />

VConnection.<br />

Cause: Error occurred while receiving an<br />

internal response.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

100903010 Error getting response code in<br />

VConnection.<br />

Cause: Error occurred while getting the<br />

code.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

100903011 Error in stopScheduledResponses of<br />

VConnection.<br />

Cause: Error occurred while attempting to<br />

stop scheduled responses.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

100903012 Error in ConsumeData of VConnection. Cause: Error occurred while reading data.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

100903013 Error in sendData of VConnection. Cause: Error occurred while sending data.<br />

Action: Ensure the server component is<br />

functioning correctly. Otherwise, submit the<br />

app_sc.0.log file for resolution.<br />

30 <strong>NetIQ</strong> <strong>Access</strong> <strong>Manager</strong> <strong>3.2</strong> <strong>SP2</strong> <strong>Event</strong> <strong>Codes</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!