Figure 4. Typical Electrical Schematic<br />

<strong>DYNA</strong> 8000 Governor<br />

}<br />

AT<br />

GENERATOR<br />

NO. 1<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

20<br />

21<br />

22<br />

23<br />

‡ KW Meter not sup<strong>pl</strong>ied by Barber-Colman<br />

10<br />

12<br />

11<br />

13<br />

16<br />

14<br />

15<br />

19<br />

24<br />

18<br />

*<br />

22 AWG<br />

10<br />

12<br />

11<br />

13<br />

DROOP ISOCHRONOUS<br />

SWITCH (SEE NOTE 6)<br />

*<br />

+<br />

-<br />

11<br />

1<br />

2<br />

3<br />

6<br />

8<br />

7<br />

9<br />

10<br />

-<br />

+<br />

B<br />

CONNECT TO<br />

SYSTEM 1<br />

BATTERY<br />

B<br />

PARALLELING LINES<br />

TO OTHER SYSTEMS<br />

CONNECT TO<br />

SYSTEM 2<br />

BATTERY {<br />

AT X<br />

+ +<br />

TO LOAD<br />

22 AWG<br />

ALTERNATE WIRING WHEN THE DROOP/ISOCHRONOUS SWITCH IS REQUIRED<br />

DROOP<br />

*<br />

ISOCHRONOUS<br />

<strong>DYNA</strong> 8000<br />

PANEL<br />

MOUNTED<br />

CONTROL<br />

SEE NOTE 8<br />

UNIT NO. 1<br />

22 AWG<br />

SHIELDED<br />

PAIRS<br />

PARALLELING LINES<br />

TO OTHER SYSTEMS<br />

DROOP ISOCHRONOUS<br />

SWITCH (SEE NOTE 6)<br />

DROOP<br />

ISOCHRONOUS<br />

X<br />

-<br />

+<br />

22 AWG<br />

PAIRS<br />

+<br />

-<br />

*<br />

10<br />

12<br />

11<br />

13<br />

10<br />

12<br />

11<br />

13<br />

16<br />

14<br />

15<br />

17<br />

19<br />

24<br />

18<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

20<br />

GENERATOR<br />

NO. 2<br />

CABLE A<br />

4 5<br />

SEE NOTE 9<br />

<strong>DYNA</strong> 8000<br />

PANEL<br />

MOUNTED<br />

CONTROL<br />

SEE NOTE 8<br />

UNIT NO. 2<br />

4<br />

5<br />

10<br />

1<br />

2<br />

3<br />

6<br />

8<br />

7<br />

9<br />

11<br />

21<br />

22<br />

23<br />

NOTE<br />

See Bulletin 16V for proper<br />

wiring.<br />

GENERATOR<br />

NO. 1<br />

CIRCUIT<br />

BREAKER<br />

AUXILIARY<br />

CIRCUIT BREAKER<br />

CONTACT<br />

AUXILIARY<br />

CIRCUIT BREAKER<br />

CONTACT<br />

GENERATOR<br />

NO. 2<br />

CIRCUIT<br />

BREAKER<br />

<br />

<br />

<br />

<br />

<br />

<br />

REMOTE<br />

SPEED<br />

POTENTIOMETER 5K<br />

CW<br />

REMOTE<br />

SPEED<br />

POTENTIOMETER<br />

5K<br />

CW<br />

SYSTEM 1<br />

BATTERY<br />

SEE NOTE 1<br />

OFF<br />

#14<br />

TWISTED<br />

PAIR<br />

ON<br />

+4 VDC<br />

<br />

<br />

A<br />

B<br />

C<br />

18 AWG<br />

SEE NOTES 2 & 3<br />

18 AWG<br />

SEE NOTES 2 & 3<br />

18 AWG<br />

SEE NOTES 2 & 3<br />

SEE NOTES 5 & 7<br />

STEPDOWN<br />

POTENTIAL<br />

TRANSFORMER<br />

AS REQUIRED<br />

FORWARD<br />

POWER<br />

RELAY<br />

REVERSE<br />

POWER<br />

RELAY<br />

DIGITAL<br />

ISOCHRONOUS<br />

LOAD<br />

SHARING<br />

CONTROL<br />

UNIT<br />

NO. 1 17<br />

22 AWG<br />

SHIELDED<br />

TRIAD<br />

UNIT<br />

NO. 2<br />

N.O.<br />

N.C.<br />

18 AWG<br />

B A<br />

MAGNETIC<br />

PICKUP<br />

DYNT<br />

C<br />

SEE NOTES 2 & 3<br />

18 AWG<br />

SEE NOTES 2 & 3<br />

18 AWG<br />

POWER SWITCH<br />

SEE NOTE 4<br />

SEE NOTES 2 & 3<br />

14 AWG<br />

TWISTED<br />

PAIR<br />

22 AWG<br />

SHIELDED<br />

TRIAD<br />

OFF<br />

SYSTEM 2<br />

BATTERY<br />

SEE NOTE 1<br />

SEE NOTES 5 & 7<br />

STEPDOWN<br />

POTENTIAL<br />

TRANSFORMER<br />

AS REQUIRED<br />

FORWARD<br />

POWER<br />

RELAY<br />

REVERSE<br />

POWER<br />

RELAY<br />

22 AWG<br />

SHIELDED<br />

TRIAD<br />

B<br />

A<br />

<br />

<br />

<br />

ON<br />

18 AWG<br />

<br />

<br />

+ 4 VDC<br />

<br />

<br />

KW<br />

METER<br />

<br />

KW<br />

METER<br />

‡<br />

‡<br />

B<br />

A<br />

SYNC<br />

SYNC<br />

MAGNETIC<br />

PICKUP<br />

DYNT<br />

SEE<br />

NOTE 7<br />

N.O.<br />

N.C.<br />

SEE<br />

NOTE 7<br />

DIGITAL<br />

ISOCHRONOUS<br />

LOAD<br />

SHARING<br />

CONTROL<br />

Uncontrolled Document<br />

18 AWG<br />

22 AWG<br />

SHIELDED<br />

PAIRS<br />

For Historical Reference Only<br />

22 AWG<br />

SHIELDED<br />

PAIRS<br />

+9 to 30 Vdc<br />

<br />

TWISTED<br />

PAIR<br />

14 AWG.<br />

TWISTED<br />

PAIR<br />

14 AWG<br />

<br />

<br />

DYNC<br />

Actuator<br />

DYNC<br />

Actuator<br />

9