VERTICAL LADDERS<br />

DIN EN ISO 14122<br />

Fixed <strong>ladders</strong> as access to machinery<br />

<strong>and</strong> equipment.<br />

min. 1.100<br />

min. 1.500 500 – 700 min. 1.500<br />

Typical application:<br />

Ladder <strong>for</strong> maintenance of process plant<br />

– Topmost rung must finish at the same level as the exit plat<strong>for</strong>m.<br />

– The ladder shall be installed with an overlap from a vertical height of 10,000 mm.<br />

The length of a ladder section must not exceed 6,000 mm.<br />

– The overlaps shall be arranged at equal intervals. May, however, be designed at a<br />

different height on request or through the online configurator.<br />

Exemption: If overlaps are not possible <strong>for</strong> structural reasons, the ladder may also be<br />

designed longer than 10,000 mm in one section. In this case, the overlap must be<br />

replaced with a rest plat<strong>for</strong>m.<br />

Exit:<br />

– In accordance with DIN EN ISO 14122-4 the exit point must meet the highest<br />

safety requirements. The exit must be secured with a self-locking gate, the gap<br />

between the ladder <strong>and</strong> the building shall not be greater than 75 mm. The ascent<br />

stile must be connected to the exit step with a 1,500 mm long rail on both sides.<br />

– The railing supplied may be omitted if it is possible to connect to a railing on the<br />

building.<br />

unter 10.000 einzügig zulässig<br />

max. 6.000<br />

max. 6.000<br />

max. 300 280<br />

400<br />

2.200 – 2.300<br />

max. 1.500<br />

max. 2.000<br />

max. 1.500<br />

2.200 – 3.000<br />

Fastening:<br />

– The st<strong>and</strong>ard wall fastening has a distance between the stile <strong>and</strong> the building<br />

of 210 mm.<br />

– Other fastening options are available, depending on the distance from the wall.<br />

– The distance between the individual fastening points shall not exceed 2,000 mm,<br />

they shall, however, preferably be mounted beneath the rungs.<br />

Ladder safety cage:<br />

– Distance from the lowest safety cage clamp to the floor: 2,200 mm to 3,000 mm.<br />

– Safety cage required from vertical height of 3,000 mm.<br />

Accessories:<br />

– Retractable, rope-operated access (page 133)<br />

– Access barriers (page 133)<br />

– Folding intermediate plat<strong>for</strong>m (page 132)<br />

– Plat<strong>for</strong>ms (page 136)<br />