Standard Roxolid ® Implants Ø 3.3 mm<br />

Regular Neck Ø 4.8 mm<br />

Art. No. Article Dimensions Material Price $<br />

SLActive ®<br />

033.431S Standard Roxolid implant SLActive 8.0 mm TiZr 445.00<br />

033.432S Standard Roxolid implant SLActive 10.0 mm TiZr 445.00<br />

033.433S Standard Roxolid implant SLActive 12.0 mm TiZr 445.00<br />

033.434S Standard Roxolid implant SLActive 14.0 mm TiZr 445.00<br />

033.435S Standard Roxolid implant SLActive 16.0 mm TiZr 445.00<br />

<strong>Straumann</strong> Standard Implants - Guided<br />

033.431G Standard Roxolid guided<br />

implant<br />

033.432G Standard Roxolid guided<br />

implant<br />

033.433G Standard Roxolid guided<br />

implant<br />

SLActive 8.0 mm TiZ 460.00<br />

SLActive 10.0 mm TiZr 460.00<br />

SLActive 12.0 mm TiZr 460.00<br />

SURGERY<br />

Closure screws and healing caps<br />

048.371V4 RN Closure screw, small internal titanium 145.00<br />

048.373V4 RN Closure screw, large height 1.5 mm titanium 145.00<br />

048.033 RN Healing cap height 2.0 mm titanium 55.00<br />

048.034 RN Healing cap height 3.0 mm titanium 55.00<br />

048.037 RN Healing cap height 4.5 mm titanium 55.00<br />

Note<br />

<strong>Straumann</strong> guided implants can be inserted fully guided through the <strong>Straumann</strong> sleeves with an internal diameter of Ø 5.0 mm.<br />

For more information on <strong>Straumann</strong>‘s Guided Implants and Instruments for Guided Surgery , please refer to the brochure “Basic<br />

Information on <strong>Straumann</strong> Guided Surgery” (USLIT 261).<br />

SLActive ®<br />

4.8<br />

mm<br />

2.8 mm<br />

Applications<br />

Standard Roxolid ®<br />

implants Ø 3.3 mm RN are an alternative in the case of a minimal ridge<br />

width of 5.5 mm and a minimal mesio-distal gap width between adjacent teeth of<br />

7.0 mm. Because of their reduced mechanical stability, small diameter implants are only<br />

used in cases with a low mechanical load. As a general rule, always use the largest<br />

possible implant diameter.<br />

3.3<br />

mm<br />

2.8<br />

mm<br />

Caution<br />

Placement in the molar region is not recommended.<br />