PRODUCT CATALOG 2012 - Straumann
PRODUCT CATALOG 2012 - Straumann
PRODUCT CATALOG 2012 - Straumann
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Surgical Instruments<br />
Single-Patient Drills (drill stop compatible)<br />
Art. No. Article Dimensions Material Price $<br />
040.440S Drill set, short, drill stop compatible<br />
for Ø 3.3 mm implant,<br />
single-patient use, sterile<br />
Ø 2.2 mm,<br />
Ø 2.8 mm,<br />
length 33.0 mm<br />
stainless<br />
steel<br />
40.00<br />
040.441S Drill set, long, drill stop compatible<br />
for Ø 3.3 mm implant,<br />
single-patient use, sterile<br />
Ø 2.2 mm,<br />
Ø 2.8 mm,<br />
length 41.0 mm<br />
stainless<br />
steel<br />
40.00<br />
040.443S Drill set, short, drill stop compatible<br />
for Ø 4.1 mm implant,<br />
single-patient use, sterile<br />
Ø 2.2 mm,<br />
Ø 2.8 mm,<br />
Ø 3.5 mm,<br />
length 33.0 mm<br />
stainless<br />
steel<br />
60.00<br />
SURGERY<br />
040.444S Drill set, long, drill stop compatible<br />
for Ø 4.1 mm implant,<br />
single-patient use, sterile<br />
Ø 2.2 mm,<br />
Ø 2.8 mm,<br />
Ø 3.5 mm,<br />
length 41.0 mm<br />
stainless<br />
steel<br />
60.00<br />
040.446S Drill set, short, drill stop compatible<br />
for Ø 4.8 mm implant,<br />
single-patient use, sterile<br />
Ø 2.2 mm,<br />
Ø 2.8 mm,<br />
Ø 3.5 mm,<br />
Ø 4.2 mm,<br />
length 33.0 mm<br />
stainless<br />
steel<br />
70.00<br />
040.447S Drill set, long, drill stop compatible<br />
for Ø 4.8 mm implant,<br />
single-patient use, sterile<br />
Ø 2.2 mm,<br />
Ø 2.8 mm,<br />
Ø 3.5 mm,<br />
Ø 4.2 mm,<br />
length 41.0 mm<br />
stainless<br />
steel<br />
70.00<br />
Application<br />
Single-patient drills are intended for all implant bed preparation procedures with the <strong>Straumann</strong> ® Dental Implant System.<br />
They are supplied sterile-packed and must only be used for one patient and one surgery. Single-patient drills can minimize the<br />
infection risk for patients, and their color coding simplifies implant bed preparation.<br />
collar for drill stop mounting<br />
Warning<br />
Single-patient drills are delivered sterile and cannot be resterilized!<br />
Resterilization renders these drills unusable.<br />
Single-patient drill, drill stop compatible (f.l.t.r.)<br />
Ø 2.2 mm, Ø 2.8 mm, Ø 3.5 mm, Ø 4.2 mm<br />
Note<br />
Single-patient drills must not be used in conjunction with<br />
<strong>Straumann</strong> Instruments for Guided Surgery.<br />
46