Surgical Instruments<br />

Single-Patient Drills (drill stop compatible)<br />

Art. No. Article Dimensions Material Price $<br />

040.440S Drill set, short, drill stop compatible<br />

for Ø 3.3 mm implant,<br />

single-patient use, sterile<br />

Ø 2.2 mm,<br />

Ø 2.8 mm,<br />

length 33.0 mm<br />

stainless<br />

steel<br />

40.00<br />

040.441S Drill set, long, drill stop compatible<br />

for Ø 3.3 mm implant,<br />

single-patient use, sterile<br />

Ø 2.2 mm,<br />

Ø 2.8 mm,<br />

length 41.0 mm<br />

stainless<br />

steel<br />

40.00<br />

040.443S Drill set, short, drill stop compatible<br />

for Ø 4.1 mm implant,<br />

single-patient use, sterile<br />

Ø 2.2 mm,<br />

Ø 2.8 mm,<br />

Ø 3.5 mm,<br />

length 33.0 mm<br />

stainless<br />

steel<br />

60.00<br />

SURGERY<br />

040.444S Drill set, long, drill stop compatible<br />

for Ø 4.1 mm implant,<br />

single-patient use, sterile<br />

Ø 2.2 mm,<br />

Ø 2.8 mm,<br />

Ø 3.5 mm,<br />

length 41.0 mm<br />

stainless<br />

steel<br />

60.00<br />

040.446S Drill set, short, drill stop compatible<br />

for Ø 4.8 mm implant,<br />

single-patient use, sterile<br />

Ø 2.2 mm,<br />

Ø 2.8 mm,<br />

Ø 3.5 mm,<br />

Ø 4.2 mm,<br />

length 33.0 mm<br />

stainless<br />

steel<br />

70.00<br />

040.447S Drill set, long, drill stop compatible<br />

for Ø 4.8 mm implant,<br />

single-patient use, sterile<br />

Ø 2.2 mm,<br />

Ø 2.8 mm,<br />

Ø 3.5 mm,<br />

Ø 4.2 mm,<br />

length 41.0 mm<br />

stainless<br />

steel<br />

70.00<br />

Application<br />

Single-patient drills are intended for all implant bed preparation procedures with the <strong>Straumann</strong> ® Dental Implant System.<br />

They are supplied sterile-packed and must only be used for one patient and one surgery. Single-patient drills can minimize the<br />

infection risk for patients, and their color coding simplifies implant bed preparation.<br />

collar for drill stop mounting<br />

Warning<br />

Single-patient drills are delivered sterile and cannot be resterilized!<br />

Resterilization renders these drills unusable.<br />

Single-patient drill, drill stop compatible (f.l.t.r.)<br />

Ø 2.2 mm, Ø 2.8 mm, Ø 3.5 mm, Ø 4.2 mm<br />

Note<br />

Single-patient drills must not be used in conjunction with<br />

<strong>Straumann</strong> Instruments for Guided Surgery.<br />

46