<strong>Rehabilitation</strong> <strong>and</strong> <strong>Expansion</strong> <strong>of</strong> <strong>the</strong> <strong>Existing</strong> WWTP in Jenin City<br />

Technical Specifications<br />

END OF SECTION<br />

SECTION 5<br />

ROOFING<br />

1-1 Corrugated Steel Ro<strong>of</strong>s<br />

All corrugated galvanised steel sheeting (whe<strong>the</strong>r fixed to wood or steel framing) shall be <strong>of</strong> 23 or 24<br />

gauge fixed with a minimum <strong>of</strong> 50mm end laps <strong>and</strong> with a minimum <strong>of</strong> one corrugation side lap.<br />

When instructed to have a one-corrugation side lap, <strong>the</strong> sheets shall have a cover <strong>of</strong> not less than 20<br />

mm <strong>and</strong> all <strong>the</strong> lapped sides shall be turned downwards. Where practicable <strong>the</strong> exposed lapped sides<br />

shall be arranged to face away from <strong>the</strong> prevailing wind. When instructed to have a one <strong>and</strong> a half<br />

corrugations side lap <strong>the</strong> sheets shall be arranged alternatively with a cover <strong>of</strong> not less than 90mm, <strong>the</strong><br />

first sheet being fixed with <strong>the</strong> lapped sides turned upwards away from <strong>the</strong> bearer <strong>and</strong> <strong>the</strong> cover sheet<br />

with <strong>the</strong> lapped sides turned downwards.<br />

Sheets shall be secured to purlins at centres not exceeding 300mm by galvanised self-parking screws<br />

(minimum 75mm long) with galvanised diamond shaped washers <strong>and</strong> lead sealing washers.<br />

All holes for bolts, self-parking screws etc. shall be punched from <strong>the</strong> underside <strong>of</strong> <strong>the</strong> sheets <strong>and</strong> shall<br />

be on <strong>the</strong> crown <strong>of</strong> <strong>the</strong> corrugations.<br />

Galvanised steel ridge capping shall be supplied <strong>and</strong> fixed to purlins as described above.<br />

1-2 Screeds<br />

Hook bolts; self-parking screws <strong>and</strong> washers shall generally comply with BS 1494.<br />

The provisions <strong>of</strong> Concrete Work section shall apply to <strong>the</strong> construction <strong>of</strong> solid reinforced concrete<br />

slab ro<strong>of</strong>s <strong>and</strong> to hollow slab ro<strong>of</strong>s. The actual finish will be specifically shown on <strong>the</strong> Drawings or in<br />

<strong>the</strong> Particular Specification.<br />

Lightweight concrete screeds for obtaining falls or as an insulation layer shall be <strong>of</strong> approved type <strong>of</strong><br />

foamed concrete. The materials shall be measured, applied <strong>and</strong> cured in accordance with <strong>the</strong><br />

manufacturer's instructions <strong>and</strong> to <strong>the</strong> satisfaction <strong>of</strong> <strong>the</strong> Engineer.<br />

In all cases <strong>the</strong> finished screed shall be <strong>of</strong> an approved proprietary type with a density <strong>of</strong> not less than<br />

400kg/ m2 to receive <strong>the</strong> applied ro<strong>of</strong>ing. Mixing shall take place using approved mechanical mixers.<br />

Concrete screeds for obtaining falls shall be (1:3:6) mix.<br />

All screeds shall be laid in bays not exceeding 10 square metres <strong>and</strong> formed between stop boards <strong>of</strong><br />

<strong>the</strong> correct height <strong>and</strong> cut on each side to indicate <strong>the</strong> slope required in <strong>the</strong> ro<strong>of</strong>ing. The screed shall<br />

<strong>the</strong>n be trowelled with a wooden float to true <strong>and</strong> accurate falls or cross falls up to <strong>the</strong> stop boards. A<br />

10mm side gap shall be left between each screed bay for <strong>the</strong> full depth <strong>of</strong> <strong>the</strong> screed. The screeds shall<br />

Arabtech Jardaneh/Palestine<br />

34<br />

Civil Works