Simplified Methods <strong>for</strong> <strong>Design</strong> <strong>of</strong> Case History<br />

Figure 9. Islais Creek Transport/Storage Project Assumed Section..<br />

Selecting a pressure diagram <strong>for</strong> the design is very difficult in the case <strong>of</strong> a multiple layer stratigraphy. Simplified pr<strong>of</strong>iles<br />

must be used to facilitate the calculations required in the simplified method. Since the least competent soil controls the<br />

lateral earth pressure, the Bay Mud was combined with other layers into one design soil unit.<br />

Two different earth pressure diagrams were constructed (Fig. 10). First, a trapezoid-shaped diagram with a maximum<br />

pressure <strong>of</strong> 51.25 kN/m 2 was calculated using an apparent earth pressure <strong>of</strong> (Weatherby, 1998):<br />

p AEP<br />

= 0.3γH (5)<br />

where p AEP is the apparent earth pressure, γ is the total unit weight <strong>of</strong> the soil and H is the height <strong>of</strong> the excavation. Using<br />

the tributary area method, the strut loads were determined as S 1 =95.8 kN, S 2 =288.1 kN and S 3 =196.4 kN.<br />

The second diagram follows suggestions by Weatherby (1998) <strong>for</strong> multiple strut walls. A maximum pressure <strong>of</strong> 45.97<br />

kN/m 2 was calculated using the “25H” trapezoid diagram. Using the tributary area method, the strut loads were determined<br />

as S 1 =79.29 kN, S 2 =189.14 kN and S 3 =147.46 kN.<br />

Once the pressure diagram and the anchor loads are known, the shear and bending moment diagrams can be drawn. The<br />

maximum moment <strong>for</strong> each diagram was calculated, as is typical in practice, at the depth <strong>of</strong> the first strut (3.14 kN·m and<br />

2.82 kN·m, respectively). Both <strong>of</strong> these moments can be safely resisted by the W30x108 wide flange beam, which was<br />

selected as rein<strong>for</strong>cement <strong>for</strong> the soil-cement columns. A major limitation <strong>of</strong> this design method is the lack <strong>of</strong> wall<br />

deflection predictions and the assumption that the maximum bending moment occurs at the first strut. The validity <strong>of</strong> this<br />

assumption will be discussed later.<br />

The lateral displacement <strong>of</strong> the wall can be predicted using the de<strong>for</strong>mation control method as described by Clough and<br />

O’Rourke (1990) and Briaud and Lim (1999). Based on the Briaud and Lim method (Fig. 3 and 4), the estimated mean<br />

deflection could range from 11.7 mm to 47.6 mm, and the estimated deflection at the top <strong>of</strong> the wall could range from 29<br />

mm to 46.8 mm using k equal to 0.3 and H equal to 11.7 m.<br />

Based on Clough and O’Rourke (1990), the shoring system stiffness (S) from Equation 1 was 128 given wall stiffness (EI)<br />

<strong>of</strong> 304,565 kN·m 2 /m (neglecting the soil-cement) and average vertical spacing between the strut supports (h) <strong>of</strong> 4.1 m. The<br />

factor <strong>of</strong> safety against basal heave was estimated using the s<strong>of</strong>tware program, XSTABLE, as 1.5. The estimated maximum<br />

horizontal movement <strong>of</strong> the system was 0.5% <strong>of</strong> the depth <strong>of</strong> the excavation, or 58 mm from Fig 5.<br />