<str<strong>on</strong>g>Guidance</str<strong>on</strong>g> - Space Requirements<br />
These dimensi<strong>on</strong>s are taken from BS8300:2001, Inclusive Mobility (DFT) and<br />
Building Sight (RNIB). They are researched average spatial requirements and<br />
should <strong>on</strong>ly be used as guidance as the needs of individuals vary.<br />
Please Note: there is a metric / imperial c<strong>on</strong>versi<strong>on</strong> table appended to this document<br />
Space allowances for people travelling <strong>on</strong> an access route<br />
Width<br />
2 wheelchair users 1800mm<br />
Wheelchair user and an ambulant pers<strong>on</strong><br />
1500mm<br />
Blind pers<strong>on</strong> with cane<br />
1200mm<br />
Pers<strong>on</strong> <strong>on</strong> crutches<br />
1200mm<br />
Blind pers<strong>on</strong> with guide dog<br />
1100mm<br />
Blind pers<strong>on</strong> with human guide<br />
1200mm<br />
Electric scooter<br />
800mm<br />
Wheelchair (occupied)<br />
800 - 900mm<br />
Adult and child<br />
1100mm<br />
Adult and helper<br />
1200mm<br />
Basic adult width<br />
500 - 600mm<br />
Length<br />
Pram and pusher<br />
Wheelchair<br />
Attendant pushed wheelchair<br />
Electric scooter<br />
Adult plus guide dog<br />
Double pushchair<br />
900mm<br />
1250mm<br />
1750mm<br />
1400mm (average)<br />
1500mm<br />
1000mm<br />
Space required to turn through 90 degrees (90% of sample)<br />
Electric wheelchair<br />
Self-propelled wheelchair<br />
Wheelchair plus attendant (max)<br />
Electric scooter (max)<br />
1600mm x 1625mm<br />
1550mm x 1550mm<br />
1800mm x 2500mm<br />
2500mm x 2500mm<br />
Unobstructed height required above a pedestrian way<br />
Minimum height required above pedestrian way<br />
Overhead signage minimum clearance<br />
Overhead signage (cycleway)<br />
Trees overhanging footway cut back to<br />
Vehicle height barriers vertical clearance<br />
2100 - 2500mm<br />
2100mm<br />
2300mm<br />
3000mm<br />
2600mm<br />
10