C 3201 - Dimotec
C 3201 - Dimotec
C 3201 - Dimotec
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
C <strong>3201</strong><br />
SUBCAB ® 4G25 mm 2<br />
4G25+2x1,5 mm 2<br />
4G35 mm 2<br />
4G35+2x1,5 mm 2<br />
Y/D start<br />
SUBCAB ® 2x4G10+2x1,5 mm 2<br />
7G6+2x1,5 mm 2<br />
Monitoring equipment<br />
Thermal contacts opening temperature 125 °C<br />
Material<br />
Impeller<br />
Cast iron<br />
Pump housing<br />
Cast iron<br />
Stator housing<br />
Cast iron<br />
Shaft<br />
Carbon steel<br />
O-rings<br />
Nitrile rubber<br />
Mechanical face seals<br />
Alternative Inner seal Outer seal<br />
1 Corrosion resistant Corrosion resistant<br />
C <strong>3201</strong><br />
cemented carbide/ cemented carbide/<br />
Corrosion resistant<br />
cemented carbide<br />
Corrosion resistant<br />
cemented carbide<br />
Product<br />
Surface Treatment<br />
All cast parts are primed with a water-borne primer. The finishing coat<br />
Submersible pump for pumping clean water, surface water and waste<br />
is a high-solid two pack paint.<br />
water containing solids or long-fibred material.<br />
Denomination<br />
Product code <strong>3201</strong>.180<br />
Weight<br />
See dimensional drawing.<br />
Process data<br />
Installation P, S, T, Z<br />
Impeller characteristics LT, MT, HT, SH<br />
Option<br />
<strong>3201</strong>.091 Ex. proof design<br />
<strong>3201</strong>.280 Stainless steel design<br />
Liquid temperature max +40 °C<br />
<strong>3201</strong>.980 Industrial design<br />
Depth of immersion<br />
max 20 m<br />
<strong>3201</strong>.290 Stainless steel/Ex proof design<br />
The pH of the pumped liquid pH 5,5-14<br />
Warm liquid version on request<br />
Liquid density max. 1100 kg/m 3 Leakage sensor in stator housing<br />
FLS<br />
Impeller throughlet<br />
See Motor rating table<br />
Leakage sensor in oil housing<br />
CLS<br />
Motor data<br />
Frequency<br />
50 Hz<br />
Surface treatment<br />
Epoxy treatment<br />
Other cables<br />
Zinc anodes<br />
Insulation class H (+180 °C)<br />
Accessories<br />
Voltage variation<br />
- continuously running max ± 5%<br />
Discharge connections, adapters, hose connections and other<br />
mechanical accessories.<br />
- intermittent running max ± 10%<br />
Electrical accessories such as pump controller, control panels, starters,<br />
Voltage imbalance between phases max 2%<br />
monitoring relays, cables.<br />
No. of starts/hour max 30<br />
See separate booklet or www.flygt.com, for further information.<br />
Cable<br />
Direct-on-line start<br />
SUBCAB ® 4G10+2x1,5 mm 2<br />
3