36 External Gear Units<br />

2<br />

Hydrostatic Fan Drive<br />

Used in material-handling systems,<br />

construction machinery, buses,<br />

HGV and passenger cars with proportional<br />

closed loop speed control.<br />

Consists of the following parts:<br />

- External gear motor with proportional<br />

pressure relief valve<br />

- Single or multi-channel electronics<br />

- Temperature sensors for fluids<br />

and air<br />

Gear motor with proportional pressure relief valve<br />

- For fan powers up to 20 kW<br />

- Proportional fan speed control<br />

- Failsafe behavior in event of power<br />

failure<br />

- Low hydraulic energy losses<br />

- Precise coolant temperature control<br />

Detailed information:<br />

Data sheet 1 987 761 700<br />

Additional information on fan<br />

drives (up to 250 kW) RE 98065<br />

Size 8 11 14 16 19 22<br />

Displacement Vg max cm³ 8 11 14 16 19 22,5<br />

Speed max. at p1 n rpm 3000 3000 3000 3000 3000 3000<br />

Prop. pressure relief valve,<br />

flow rate<br />

Qmax l/min 150 150 150 150 150 150<br />

Prop. pressure relief valve,<br />

operating pressure<br />

Pmax bar 220 220 220 220 220 220<br />

Solenoid voltage U V 12, 24 12, 24 12, 24 12, 24 12, 24 12, 24<br />

Power consumption,<br />

solenoid<br />

P W 18 18 18 18 18 18<br />

Weight<br />

Single-channel electronics<br />

m kg 3,5 3,6 3,8 4 4,2 4,4<br />

Type<br />

Analog control amplifier with voltage regulator, an analog input, working range adaptation and a power output<br />

with short-circuit protection for one proportional valve.<br />

Electrical connection 6-pin<br />

Operating voltage<br />

Multi-channel electronics<br />

11...36 V<br />

Type<br />

Analog control amplifier with voltage regulator, setpoint/actual value comparison for three analog inputs,<br />

one switch input and one power output with short-circuit protection for one proportional valve.<br />

Electrical connection 15 pin<br />

Operating voltage 11...36 V<br />

PTC sensors<br />

Type Fluid Air<br />

Measurement range -30 °C ... 130 °C -40 °C ... 130 °C