7. Incorrect Blood Component Transfused (IBCT)<br />
Definition<br />
The category Incorrect Blood Component Transfused (IBCT) comprises all reported episodes where a patient was<br />
transfused with a blood component that was intended for another patient or which was incorrect in terms <strong>of</strong> its<br />
specification.<br />
DATA SUMMARY<br />
Total number <strong>of</strong> cases 282 Implicated components Mortality/morbidity<br />
Gender<br />
Age<br />
Red cells 220 Deaths due to transfusion 0<br />
FFP 17<br />
Deaths in which reaction possibly<br />
contributed<br />
Platelets 26 Major morbidity 4<br />
Other (specify)<br />
Unknown 19<br />
Emergency vs. routine and core<br />
hours vs. out <strong>of</strong> core hours<br />
Where transfusion took place<br />
3<br />
Male<br />
Female<br />
Unknown<br />
132<br />
145<br />
5<br />
18 years+<br />
16 years+ to 18 years<br />
1 year+ to 16 years<br />
28 days+ to 1 year<br />
Birth to 28 days<br />
unknown<br />
Total<br />
242<br />
3<br />
21<br />
9<br />
7<br />
282<br />
Emergency<br />
Routine<br />
Not known<br />
In core hours<br />
Out <strong>of</strong> core hours<br />
Not known/applicable<br />
60<br />
189<br />
33<br />
82<br />
45<br />
155<br />
ED<br />
Theatre<br />
ITU/NNU/HDU/Recovery<br />
Wards<br />
Community<br />
Outpatient/day unit<br />
Not known<br />
4<br />
9<br />
14<br />
76<br />
1<br />
10<br />
168<br />
As in the 2008 report, this chapter comprises reports on 4 main types <strong>of</strong> errors which result in the transfusion <strong>of</strong> an<br />
incorrect blood component (plus 2 miscellaneous cases):<br />
■■<br />
■■<br />
■■<br />
■■<br />
Bedside blood administration errors<br />
Laboratory errors, testing and process errors<br />
Phlebotomy errors resulting in ‘wrong blood in tube’ (WBIT)<br />
<strong>Transfusion</strong> <strong>of</strong> components not meeting the patient’s special requirements (SRNM).<br />
The SRNM cases are divided according to whether they are clinical errors, largely <strong>of</strong> knowledge and/or communication<br />
(so that the transfusion laboratory did not know <strong>of</strong> the special requirement), and those which originated in the laboratory<br />
(in which the necessary information was available but not acted upon).<br />
In <strong>2009</strong> a total <strong>of</strong> 282 IBCT reports were received, which is a 7.6% increase compared with 2008, when 262 cases were<br />
included. The rate <strong>of</strong> reports <strong>of</strong> IBCT for <strong>2009</strong> was 9.7 per 100,000 components issued by the UK blood transfusion<br />
services compared with 9.2 in 2008.<br />
The data summary above shows that the data on cases in core hours and out <strong>of</strong> hours, and for the location <strong>of</strong> the patient<br />
when the error occurred, were poorly completed on the questionnaires. There were a total <strong>of</strong> 40 cases <strong>of</strong> IBCT occurring<br />
in patients under 18 years <strong>of</strong> age and these are discussed in more detail in the paediatrics chapter on page 140. The<br />
age range among adults was 18–97 years <strong>of</strong> age.<br />
7. Incorrect Blood Component Transfused (IBCT) 27