7. Incorrect Blood Component Transfused (IBCT)<br />

Definition<br />

The category Incorrect Blood Component Transfused (IBCT) comprises all reported episodes where a patient was<br />

transfused with a blood component that was intended for another patient or which was incorrect in terms <strong>of</strong> its<br />

specification.<br />

DATA SUMMARY<br />

Total number <strong>of</strong> cases 282 Implicated components Mortality/morbidity<br />

Gender<br />

Age<br />

Red cells 220 Deaths due to transfusion 0<br />

FFP 17<br />

Deaths in which reaction possibly<br />

contributed<br />

Platelets 26 Major morbidity 4<br />

Other (specify)<br />

Unknown 19<br />

Emergency vs. routine and core<br />

hours vs. out <strong>of</strong> core hours<br />

Where transfusion took place<br />

3<br />

Male<br />

Female<br />

Unknown<br />

132<br />

145<br />

5<br />

18 years+<br />

16 years+ to 18 years<br />

1 year+ to 16 years<br />

28 days+ to 1 year<br />

Birth to 28 days<br />

unknown<br />

Total<br />

242<br />

3<br />

21<br />

9<br />

7<br />

282<br />

Emergency<br />

Routine<br />

Not known<br />

In core hours<br />

Out <strong>of</strong> core hours<br />

Not known/applicable<br />

60<br />

189<br />

33<br />

82<br />

45<br />

155<br />

ED<br />

Theatre<br />

ITU/NNU/HDU/Recovery<br />

Wards<br />

Community<br />

Outpatient/day unit<br />

Not known<br />

4<br />

9<br />

14<br />

76<br />

1<br />

10<br />

168<br />

As in the 2008 report, this chapter comprises reports on 4 main types <strong>of</strong> errors which result in the transfusion <strong>of</strong> an<br />

incorrect blood component (plus 2 miscellaneous cases):<br />

■■<br />

■■<br />

■■<br />

■■<br />

Bedside blood administration errors<br />

Laboratory errors, testing and process errors<br />

Phlebotomy errors resulting in ‘wrong blood in tube’ (WBIT)<br />

<strong>Transfusion</strong> <strong>of</strong> components not meeting the patient’s special requirements (SRNM).<br />

The SRNM cases are divided according to whether they are clinical errors, largely <strong>of</strong> knowledge and/or communication<br />

(so that the transfusion laboratory did not know <strong>of</strong> the special requirement), and those which originated in the laboratory<br />

(in which the necessary information was available but not acted upon).<br />

In <strong>2009</strong> a total <strong>of</strong> 282 IBCT reports were received, which is a 7.6% increase compared with 2008, when 262 cases were<br />

included. The rate <strong>of</strong> reports <strong>of</strong> IBCT for <strong>2009</strong> was 9.7 per 100,000 components issued by the UK blood transfusion<br />

services compared with 9.2 in 2008.<br />

The data summary above shows that the data on cases in core hours and out <strong>of</strong> hours, and for the location <strong>of</strong> the patient<br />

when the error occurred, were poorly completed on the questionnaires. There were a total <strong>of</strong> 40 cases <strong>of</strong> IBCT occurring<br />

in patients under 18 years <strong>of</strong> age and these are discussed in more detail in the paediatrics chapter on page 140. The<br />

age range among adults was 18–97 years <strong>of</strong> age.<br />

7. Incorrect Blood Component Transfused (IBCT) 27