12Vdc<br />

HP StorageWorks<br />

4/32B <strong>SAN</strong> Swit<strong>ch</strong><br />

0 4 1 5 2 6 3 7<br />

8 12 9 13 10 14 1 15<br />

16 20 17 21 18 2 19 23<br />

24 28 25 29 26 30 27 31<br />

UID<br />

HP 4Gb VC-FC Module<br />

PS 1<br />

Cntrl 1<br />

1 2 DP1-A DP1-B<br />

1 2 DP1-A DP1-B<br />

1 2 3 4<br />

12Vdc<br />

UID<br />

Mfg<br />

Mgmt<br />

HP ProLiant<br />

BL460c<br />

UID<br />

NIC<br />

1<br />

NIC<br />

2<br />

UID<br />

Cntrl 2<br />

HP 4Gb VC-FC Module<br />

UID<br />

UID<br />

12Vdc<br />

Mfg<br />

PS 2<br />

HP StorageWorks<br />

4/32B <strong>SAN</strong> Swit<strong>ch</strong><br />

0 4 1 5 2 6 3 7<br />

8 12 9 13 10 14 1 15<br />

16 20 17 21 18 2 19 23<br />

24 28 25 29 26 30 27 31<br />

1 2 3 4<br />

12Vdc<br />

Figure 7: Physical view<br />

Storage Array<br />

Fabric-1<br />

Fabric-2<br />

HBA 1 HBA 2<br />

Blade Server<br />

Benefits<br />

This configuration offers the simplicity of managing only one redundant fabric with a single uplink.<br />

Transparent failover is managed by a multipathing I/O driver running in the server Operation System.<br />

This scenario maximizes the use of the VC Fabric uplink ports, reduces the total number of swit<strong>ch</strong> ports<br />

needed in the datacenter and saves money as Fabric ports can be expensive.<br />

Considerations<br />

In a fully populated c7000 enclosure, the server-to-uplink ratio is 16:1; this configuration may result in<br />

poor response time and may require particular performance monitoring attention.<br />

A failure somewhere between VC and the external fabric can disrupt all server I/O operations if a<br />

properly configured multipathing I/O driver running in the server Operating System is not used.<br />

The <strong>SAN</strong> swit<strong>ch</strong> ports connecting to the VC-FC modules must be configured to accept NPIV logins.<br />

Requirements<br />

This configuration requires two VC <strong>SAN</strong> fabrics with two <strong>SAN</strong> swit<strong>ch</strong>es that support NPIV, at least two<br />

VC-FC modules, and at least two VC fabric uplink ports connected to the redundant <strong>SAN</strong> fabric.<br />

Scenario 1: Simplest scenario with multipathing 26