The automatic failover allows smooth transition without mu<strong>ch</strong> disruption to the traffic. However, the hosts<br />

will have to perform re-login before resuming their I/O operations. Only a redundant <strong>SAN</strong> fabric with a<br />

multipathing I/O driver running in the server Operation System can provide a complete transparent<br />

transition.<br />

Requirements<br />

This configuration requires two VC <strong>SAN</strong> fabrics with two <strong>SAN</strong> swit<strong>ch</strong>es that support NPIV, at least two<br />

VC-FC modules, and at least four VC fabric uplink ports connected to the redundant <strong>SAN</strong> fabric.<br />

For more information about configuring FC swit<strong>ch</strong>es for NPIV, see "Appendix C: Brocade <strong>SAN</strong> swit<strong>ch</strong><br />

NPIV configuration" or "Appendix D: Cisco <strong>SAN</strong> swit<strong>ch</strong> NPIV configuration" or "Appendix E: Cisco<br />

NEXUS <strong>SAN</strong> swit<strong>ch</strong> NPIV configuration" depending on your swit<strong>ch</strong> model.<br />

Installation and configuration<br />

Swit<strong>ch</strong> configuration<br />

Appendices B, C and D provide the steps required to configure NPIV on the upstream <strong>SAN</strong> swit<strong>ch</strong> in a<br />

Brocade, Cisco MDS or Cisco Nexus Fiber Channel infrastructure.<br />

VC CLI commands<br />

In addition to the GUI, many of the configuration settings within VC can be also be accomplished via a<br />

CLI command set. In order to connect to VC via a CLI, open an SSH connection to the IP address of the<br />

active VCM. Once logged in, VC provides a CLI with help menus. The <strong>Virtual</strong> <strong>Connect</strong> CLI guide also<br />

provides many useful examples. Throughout this scenario the CLI commands to configure VC for ea<strong>ch</strong><br />

setting are provided.<br />

Configuring the VC module<br />

Physically connect the uplink ports on the first VC-FC module to swit<strong>ch</strong> port in <strong>SAN</strong> Fabric 1<br />

Physically connect the uplink ports on the second VC-FC module to swit<strong>ch</strong> port in <strong>SAN</strong> Fabric 2<br />

Defining a new VC <strong>SAN</strong> Fabric via GUI<br />

To configure the VC-FC modules from the HP <strong>Virtual</strong> <strong>Connect</strong> Manager home screen:<br />

Scenario 2: VC <strong>SAN</strong> fabrics with Dynamic Login Balancing connected to the same redundant <strong>SAN</strong> fabric 36