SA-VK61DGS
SA-VK61DGS
SA-VK61DGS
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>SA</strong>-<strong>VK61DGS</strong><br />
Item<br />
Operational<br />
Condition and Key<br />
Function<br />
Jitter display While the player is<br />
stopped and no disc is<br />
inserted, press and<br />
hold down the<br />
button on the player<br />
and the number<br />
button, “5” on the<br />
remote controller unit.<br />
Error code display While the player is<br />
stopped and no disc is<br />
inserted, press and<br />
hold down the<br />
button on the player<br />
and the number<br />
button, “0” on the<br />
remote controller unit.<br />
Measurement of laser<br />
current electricity<br />
initialization value<br />
While the player is<br />
stopped and no disc is<br />
inserted, press and<br />
hold down the<br />
button on the player<br />
and the button<br />
on the remote<br />
controller unit.<br />
Measurement of DVD While the player is<br />
laser current electricity stopped and no disc is<br />
inserted, press and<br />
hold down the<br />
button on the player<br />
and the DISPLAY<br />
button on the remote<br />
controller unit.<br />
Details Display TO Exit Mode<br />
Jitter display<br />
J *1 xxx *2 _yyy *3 _zz *4<br />
Measures and displays jitter.<br />
Measurement is repeated every<br />
second. Read error counter starts at 0<br />
at the mode setting, and increased by<br />
one as data read fails at target block. A<br />
small defect is allowed to correct by<br />
retry. Any possibility is counted as one<br />
increment. Repetitive errors after retry<br />
increase by two levels or more.<br />
Error code display<br />
Displays the latest error code stored in<br />
EEPROM.<br />
Measurement of laser current<br />
electricity initialization value<br />
Memorizes each initialization value of<br />
DVD and CD in EEPROM.<br />
Measurement of DVD laser current<br />
electricity<br />
Measures DVD laser current electricity<br />
and displays the result together with<br />
the initialization value stored in<br />
EEPROM. After measurement, DVD<br />
laser is lit till the power is turned off (or<br />
goes off when the primary power is<br />
turned off).<br />
*1 : Jitter display mode<br />
*2 : Jitter measurement value<br />
*3 : Read error counter<br />
*4 : Focus driving value<br />
Values are shown to one decimal<br />
place in the decimal digit.Focus<br />
driving value is displayed in the<br />
hexadecimal digit.<br />
DVDnn_F---<br />
*nn: Error history<br />
*--: Error number<br />
DVD 01 FOBF<br />
LDO *1 _013 *2 _032 *3<br />
*1 : Laser current electricity<br />
measurement mode<br />
*2 : DVD current electricity value<br />
*3 : CD current electricity value<br />
Values are shown in the decimal<br />
digit. The above example indicates<br />
that the current electricity<br />
initialization value is 13mA at DVD<br />
laser and 32mA at CD laser when<br />
laser is turned on.<br />
LDD *1 _012 *2 _014 *3<br />
*1 : DVD laser current electricity<br />
measurement mode<br />
*2 : Current electricity initialization<br />
value stored in EEPROM<br />
*3 : Present value of current<br />
electricity<br />
Press the STOP or<br />
OPEN button.<br />
Press the OPEN<br />
button.<br />
Automatically exits<br />
the mode after five<br />
seconds.<br />
Automatically exits<br />
the mode after five<br />
seconds.<br />
ADSC internal RAM<br />
display<br />
While the player is ADSC internal RAM display<br />
stopped and no disc is<br />
inserted, press and<br />
hold down the<br />
button on the player<br />
and the number button<br />
“1” or “2” on the remote<br />
controller unit.<br />
Reads and displays the RAM value<br />
inside ADSC. The address is renewed<br />
when the CLEAR key is pressed so<br />
that the values at eleven points appear.<br />
Values are shown in the decimal<br />
digit. The above example indicates<br />
that the current electricity<br />
initialization value is 12mA and its<br />
present value is 14mA.<br />
A *1 _FB0 *2 _0000 *3<br />
*1 :ADSC internal RAM display<br />
mode<br />
*2 : Address<br />
*3 : RAM value at displayed<br />
address<br />
Press the STOP or<br />
OPEN button.<br />
Values are shown in the<br />
hexadecimal digit. The above<br />
example indicates that ADSC<br />
value at the address, FB0h is<br />
0000h.<br />
26