04.11.2012 Views

Product Overview 2010 - Lokshop

Product Overview 2010 - Lokshop

Product Overview 2010 - Lokshop

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LokSound XL<br />

V3.0 M4<br />

LokSound XL<br />

V3.5<br />

LokSound<br />

micro V3.5<br />

LokSound<br />

V3.0 M4<br />

LokSound<br />

V3.5<br />

LokPilot XL<br />

V3.0<br />

LokPilot<br />

micro V3.0<br />

DCC<br />

LokPilot<br />

micro V3.0<br />

LokPilot<br />

V3.0 DCC<br />

LokPilot<br />

V3.0<br />

LokPilot<br />

V3.0 M4<br />

LokPilot Fx<br />

micro V3.0<br />

LokPilot Fx<br />

V3.0<br />

LokPilot<br />

Basic V1.0<br />

ESU Decoder comparison chart<br />

Operational modes<br />

DCC 14, 28, 128 speed steps OK OK OK - OK OK OK OK OK OK - OK OK -<br />

DCC short addresses OK OK OK - OK OK OK OK OK OK - OK OK -<br />

DCC long addresses OK OK OK - OK OK OK OK OK OK - OK OK -<br />

DCC consist Mode - OK OK - OK OK OK OK OK OK - OK OK -<br />

DCC LGB pulse control - OK OK - OK OK OK OK OK OK - OK OK -<br />

automatic speed step detection - OK OK - OK OK OK OK OK OK - OK OK -<br />

Lenz LG 100, ROCO brake unit OK OK OK - OK OK OK OK OK OK - OK OK -<br />

ZIMO HLU-commands - OK - - OK OK - OK OK - - OK - -<br />

DC analog mode OK OK OK - OK OK OK OK OK OK - OK OK -<br />

Motorola® 14 speed steps - OK OK OK OK - OK - OK OK OK OK OK OK<br />

Motorola® 28 speed steps - OK OK OK OK OK OK - OK OK OK - OK OK<br />

Motorola® address 1 - 80 - OK OK OK OK - OK - OK OK OK OK OK OK<br />

Motorola® address 1 - 127 - OK OK OK OK - OK - OK OK OK OK OK OK<br />

Motorola® address 1 - 255 - - - OK OK - - - OK - OK - - OK<br />

Märklin® brake unit - OK OK OK OK - OK - OK OK OK OK OK OK<br />

Selectrix® - OK OK - OK - OK - - - - OK - -<br />

AC analog mode - OK - OK OK - - - OK OK OK - OK OK<br />

Automatic detection of operational mode OK OK OK OK OK OK OK OK OK OK OK OK OK OK<br />

Throttle<br />

DC and coreless motors<br />

AC motors with permanent magnet OK - - OK OK OK OK OK OK OK OK OK OK OK<br />

PWM frequency 31.25 kHz - - 32.00 kHz 32.00 kHz 32.00kHz 32.00 kHz 32.00 kHz 32.00 kHz 32.00 kHz 32.00 kHz 32.00 kHz 32.00 kHz 32.00 kHz<br />

Load control in digital mode OK - - OK OK OK OK OK OK OK OK OK OK OK<br />

Load control in analog mode - - - - OK OK OK OK OK OK - OK OK OK<br />

Einstellb. Anfahr- & Höchstgeschw. im Analogbetrieb - - - OK OK OK OK OK OK OK OK OK OK OK<br />

Massensimulation für 14 Fahrstufenbetrieb - - - OK OK OK OK OK OK OK OK OK OK OK<br />

DDC (Dynamic Drive Control) - - - - OK OK OK OK OK OK - OK OK OK<br />

Continuous motor current 0.7A - - 1.1A 1.1A 1.1A 0.75A 0.75A 3.0A 1.1A 1.1A 0.5A 3.0A 3.0A<br />

Short circuit protection OK - - OK OK OK OK OK OK OK OK OK OK OK<br />

Function outputs<br />

Number of function outputs 3 6 4 4 4 4 2 2 8 4 4 4 8 6<br />

Current of each output 180mA 250mA 140mA 250mA 250mA 250mA 140mA 140mA 600mA 250mA 250mA 180mA 600mA 600mA<br />

Short circuit protection OK OK OK OK OK OK OK OK OK OK OK OK OK OK<br />

Brightness control for outputs combined separate separate separate separate separate separate separate separate separate separate separate separate separate<br />

Light effects like Blinking lights, Strobe, Gyra light,<br />

Mars light, zoom, Firebox flickering, Ditch light - OK OK OK OK OK OK OK OK OK OK OK OK OK<br />

Timer-controlled function outputs - OK OK - OK OK OK OK OK - - - - -<br />

Function Mapping acc. to NMRA (F0 to F8) - - - - - - - - - - - - - -<br />

Function Mapping acc. to ESU (F0 to F15) - OK OK - OK OK OK (F12) OK (F12) OK OK - OK OK -<br />

Function Mapping M4 with icon assignment - - - OK - - - - - - OK - - OK<br />

Switcher mode (de-selectable) OK - - OK OK OK OK OK OK OK OK OK OK OK<br />

ABV de-selectable OK - - OK OK OK OK OK OK OK OK OK OK OK<br />

Sound<br />

Polyphonic 4-channel sound - - - - - - - - - OK OK OK OK OK<br />

Flash memory for sound data - - - - - - - - - 16 MBit 16 Mbit 16 Mbit 16 Mbit 16 Mbit<br />

Power of BTL amplifier (sinus) - - - - - - - - - 0.6W 0.6W 0.5W 1.5W 1.5W<br />

Programming<br />

DCC service mode programming modes<br />

(Register Mode, Address Only, Direct Mode) OK OK OK - OK OK OK OK OK OK - OK OK -<br />

DCC POM (Programming On the Main) - OK OK - OK OK OK OK OK OK - OK OK -<br />

Programmng mode for Märklin® 6021® - OK OK OK OK - OK OK - OK OK OK OK OK<br />

M4 configuration on the main track - - - OK - - - - - - OK - - OK<br />

Specials<br />

M4 feedback system - - - OK - - - - - - OK - - OK<br />

RailCom® feedback system - OK OK - OK OK - OK OK - - - - -<br />

Storage of current operational state (memory) - - - OK OK OK OK OK OK OK OK OK OK OK<br />

Motorola® wrong-direction bit - OK OK OK OK - OK - OK OK OK OK OK OK<br />

Construction<br />

Dimensions in mm 25.5x15.5x4.5 17.5x15.5x5.5 13.5x9.0x3.0 23.0x15.5x5.5 23.0x15.5x5.5 13.5x9.0x4.5 13.5x9.0x4.5 13.5x9.0x3.0 55.0x25.0x10 31.0x15.5x6.5 31.0x15.5x6.5 28.0x10.0x5.0 51.0x40.0x14.0 51.0x40.0x14.0<br />

8-pin plug NEM652 with cable harness 52690 52620 - 61600 52610 52611 - - - 524xx 624xx - - -<br />

6-pin lpug S NEM651with cable harness - 52624 - 52612 52613 52687 52684 - - - 528xx - -<br />

6-pin plug NEM651 - - - - 52688 52685 - - - - - -<br />

21MTC connector 52692 52621 - 61601 52614 - - - - 52499 62499 - - -<br />

Screw terminals - - - - - - 51702 - - - 525xx 62500<br />

61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!